Warning of flammable substances
Handling fuels entails a risk of fire.
Take sufficient precautions when handling fuels such
as fuel oil, kerosene or diesel.
Do not spill any diesel, kerosene or fuel oil! Do not
inhale the vapours nor swallow any fuel! Avoid skin
contact!
Warning of hot surface
Parts of the device, especially at the air outlet, become
very hot during operation. There is a danger of burning
and fire. Do not touch the device during operation!
During operation observe a safety distance of at least
3 m to the device front! Observe the minimum distance
from walls or other objects according to the technical
data!
Warning of hot surface
Some parts of this product can become very hot and
cause burns. Particular attention has to be given where
children and vulnerable people are present!
Warning of hot surface
Improper handling entails a risk of burning. Only use
the device as intended!
Warning
Improper handling entails a risk of burning and electric
shock.
Only use the device as intended!
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
Improper installation entails a risk of fire.
Do not place the device on combustible ground.
Do not place the device on high-pile carpets.
Warning
The device must not be covered, there is an imminent
fire hazard!
Behaviour in the event of an emergency
1. In case of an emergency, immediately extinguish the pilot
flame by actuating the on/off switch (position
0
).
2. In an emergency, disconnect the device from the mains
feed-in: Switch the device off and disconnect it from the
mains.
3. Remove persons from the danger area.
4. Do not reconnect a defective device to the mains.
Overheating protection
The device is provided with a safety thermostat which is
activated by overheating of the device (when exceeding the
operating temperature).
Investigate the cause of overheating.
If the safety thermostat does not switch in the event of
overheating, the overheating protection will be tripped. In that
case the device switches off completely. If so, please contact
the customer service to have the overheating protection
replaced.
Information about the device
Device description
The directly fired oil heater
IDX 30 D
serves the purpose of
heating the room air so as to quickly heat large, well-ventilated
rooms. The oil heater runs on EL fuel oil, kerosene or diesel, it
must not be used with petrol, heavy fuel oil etc.
It is an oil heater with direct combustion to be installed in roofed
outdoor areas or in rooms with a sufficient fresh air supply.
Functional principle
The device generates warmth by conveying the sucked-in, cold
air past a combustion chamber. Inside the combustion chamber
the fuel is burned. The sucked-in air is heated and fed back to
the environment via the air outlet.
A part of the sucked-in air is compressed and conducted to the
injection. The fuel is fed from the tank to the injection by the
negative pressure thus created. An ignition contact at the
injection ignites the fuel, which is then burned in a continuous
flame.