background image

7

EN

oil heater IDX 30 D

Operation

The device may only be used by accordingly instructed persons.

Operating elements

25 30

35

40

45

5

10

15

20

13

14

15

16

No.

Designation

13

Operating LED

14

Temperature indication

15

ON/OFF switch

16

Rotary control thermostat

Switching the device on

The device continues to operate until the desired room
temperature is reached.

1. Set the on/off switch (15) to position 

I

.

ð

The operating light (13) is illuminated.

2. Set the rotary control (16) to the desired room

temperature. This value should be higher than the current
room temperature.

ð

The desired room temperature is displayed via the
temperature indication (14).

3. Ensure a successful ignition.

Switching the device off

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Note

Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Only pull the mains plug
once the fan motor has stopped completely.

1. Switch off the device by setting the on/off switch (15) to

position 

0

.

ð

The operating light (13) goes out.

2. Wait until the fan motor has come to a complete standstill.
3. Secure the device against inadvertent switch-on by pulling

the mains plug.

4. Allow the device to cool down completely.

Errors and faults

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

Warning

Risk of injury due to improper repair!
Never try to make any modifications or repairs on the
device.
Unauthorised modifications can lead to serious injuries
or death.
Have a certified specialist workshop perform the repair
work.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

The operating light is not illuminated:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

The safety thermostat might have tripped due to
overheating Switch the device off and let it cool down for
at least 10 minutes.

The device starts running, but switches off again after a
brief period:

The operating light flashes:

The pump pressure might be incorrect. Check the pressure
at the pump and adjust it if necessary, see chapter
Adjusting the air pressure for the pump.

The air filters might be dirty. Clean the air filters, and
replace them if necessary, see chapter Cleaning air filters
and fan.

The fan is running, but the device does not start:

The operating light flashes:

There might be no fuel in the tank. Check the filling level of
the tank. Refill fuel if the tank is empty (see chapter Filling
the tank).

The pump pressure might be incorrect. Check the pressure
at the pump and adjust it if necessary, see chapter
Adjusting the air pressure for the pump.

The fan does not start, even though the device is connected
and switched on:

The operating light flashes:

The thermostat setting might be too low. Turn up the
thermostat setting.

Summary of Contents for IDX 30 D

Page 1: ...TRT BA IDX30D TC 002 EN IDX 30 D EN ORIGINAL INSTRUCTIONS OIL HEATER ...

Page 2: ...ia the following link IDX 30 D https hub trotec com id 40041 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instru...

Page 3: ...the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Do not use the device in immediate proximity to curtains Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not place the device on combustible ground Only tran...

Page 4: ...here is an imminent fire hazard Behaviour in the event of an emergency 1 In case of an emergency immediately extinguish the pilot flame by actuating the on off switch position 0 2 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 3 Remove persons from the danger area 4 Do not reconnect a defective device to the mains Overheating pro...

Page 5: ...follows Switch off the device Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently While transporting the device observe the following Slightly lift the device by the transport handle 2 until the rear support no longer touches the ground Wheel the device to the desired position Storag...

Page 6: ...e axle must be attached to the frame To do so please proceed as follows 1 Slide the axle through the openings at the frame 2 Attach both wheels to the axle 3 Attach the locking rings to the axle 4 Fasten the wheel caps to the wheels Info If necessary the frame can be disassembled again e g for storage To remove the wheels from the axle you can carefully loosen the wheel caps and locking rings by m...

Page 7: ...ls or large objects near the device The inlet and outlet openings must not be covered There must be a sufficient number of fire extinguishers available 25 30 35 40 45 5 10 15 20 3 m 3 m 3 m 3 m 3 m Start up Check the scope of delivery of your device for completeness If an accessory part is missing please contact the Trotec customer service or the specialist dealer where you purchased the device Ch...

Page 8: ...specialist companies or by Trotec Warning Risk of injury due to improper repair Never try to make any modifications or repairs on the device Unauthorised modifications can lead to serious injuries or death Have a certified specialist workshop perform the repair work The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device...

Page 9: ...the cause on the basis of the following criteria For qualified personnel only Check the ignition The distance between the two ignition electrodes should be 4 to 5 mm The flame goes out during combustion Make sure the air supply is unobstructed If required clean the air intake opening Check the filling level of the tank Refill with fuel if the tank is empty see chapter Operation Moisture in tank or...

Page 10: ...y after cleaning Filling the tank The fuel tank cap and the filling level indication are located to the left of the control panel ü Before attempting to fill the tank wait until the device has cooled down completely ü Only use fuel suitable for the device see technical data 1 Position the device on firm level and incombustible ground 2 Unscrew the fuel tank cap 9 IDX 30 D THERMOSTAT CONTROL ROOM T...

Page 11: ...r filters should be checked cleaned and possibly replaced approx every 500 operating hours The fan ought to be checked for dirt at least once per heating season This activity can be carried out along with the inspection of the air filters Overview of air filters The filter housing consists of the following parts filter seal 30 prefilter 31 foam filter 32 filter housing 33 30 31 32 33 Opening the h...

Page 12: ...T CONTROL ROOM TEMP CLOSE OPEN IDX 30 D Cleaning the fan blades 1 Carefully clean the fan blades with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth THERMOSTAT CONTROL ROOM TEMP 0 6 0 8 1 0 0 2 0 4 ...

Page 13: ...leaning or replacement 1 Remove the two filters from the filter housing 33 30 31 32 33 2 Check both filters for dirt or damage Replace the prefilter 31 if needed If required clean the foam filter 32 using a slightly damp soft lint free cloth If the foam filter is heavily contaminated clean it with warm water mixed with a neutral cleaning agent 3 Allow the foam filter to dry completely Do not put a...

Page 14: ...lter housing 33 Ensure the proper seating of the seal 30 30 31 32 33 Assembling the filter housing 1 Attach the filter housing with filters and sealing 2 Tighten the hexagonal bolts at the filter housing 3 Fasten the pressure gauge in place 0 6 0 8 1 0 0 2 0 4 ...

Page 15: ... the housing on the device THERMOSTAT CONTROL ROOM TEMP CLOSE OPEN IDX 30 D 2 Tighten the 8 screws at the upper part of the housing IDX 30 D THERMOSTAT CONTROL ROOM TEMP 0 6 0 8 1 0 0 2 0 4 CLOSE OPEN 3 Attach the protective grid IDX 30 D 4 Tighten the 4 screws at the protective grid IDX 30 D ...

Page 16: ...ted screwdriver For lowering turn the screw counter clockwise for increasing carefully turn it clockwise 0 6 0 8 1 0 0 2 0 4 Technical annex Technical data Parameter Value Article number 1 430 000 066 Method of heating direct Amount of air 735 m h Fan Axial fan Mains connection 1 N PE 220 240 V 50 Hz Nominal heat output 30 kW 25 800 kcal Temperature increase ΔT 90 C 1 5 m distance Input voltage 23...

Page 17: ...EN 16 oil heater IDX 30 D Wiring diagram ...

Page 18: ...17 EN oil heater IDX 30 D Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual ...

Page 19: ... Grounding Plate 35 Fuel Line Hose 5 4 Rotor Kit 15 Fixation Part 36 Ignitor Wire 5 5 Blade 16 Fuel Tank 37 Photocell 5 6 End Pump Cover 17 Supporting Bracket 38 Photocell Bracket 5 7 Output Filter small 18 Power Cord 39 Fuel Gauge Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household w...

Page 20: ...version 2006 42 EC Product model Product IDX 30 D Product type oil heater Year of manufacture as of 2018 Relevant EU directives 2014 30 EU 29 March 2014 Applied harmonised standards EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 2015 EN 60335 1 2012 EN 60335 1 2012 A11 2014 EN 60335 2 30 2009 A11 2012 AC 2014 EN 60335 2 102 2016 EN 61000 3 2 2014 EN 61000 3 3 2013 Applied national standards and techni...

Page 21: ......

Page 22: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: