7
EN
oil heater IDX 30 D
Operation
The device may only be used by accordingly instructed persons.
Operating elements
25 30
35
40
45
5
10
15
20
13
14
15
16
No.
Designation
13
Operating LED
14
Temperature indication
15
ON/OFF switch
16
Rotary control thermostat
Switching the device on
The device continues to operate until the desired room
temperature is reached.
1. Set the on/off switch (15) to position
I
.
ð
The operating light (13) is illuminated.
2. Set the rotary control (16) to the desired room
temperature. This value should be higher than the current
room temperature.
ð
The desired room temperature is displayed via the
temperature indication (14).
3. Ensure a successful ignition.
Switching the device off
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Only pull the mains plug
once the fan motor has stopped completely.
1. Switch off the device by setting the on/off switch (15) to
position
0
.
ð
The operating light (13) goes out.
2. Wait until the fan motor has come to a complete standstill.
3. Secure the device against inadvertent switch-on by pulling
the mains plug.
4. Allow the device to cool down completely.
Errors and faults
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Warning
Risk of injury due to improper repair!
Never try to make any modifications or repairs on the
device.
Unauthorised modifications can lead to serious injuries
or death.
Have a certified specialist workshop perform the repair
work.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
The operating light is not illuminated:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
The safety thermostat might have tripped due to
overheating Switch the device off and let it cool down for
at least 10 minutes.
The device starts running, but switches off again after a
brief period:
The operating light flashes:
•
The pump pressure might be incorrect. Check the pressure
at the pump and adjust it if necessary, see chapter
Adjusting the air pressure for the pump.
•
The air filters might be dirty. Clean the air filters, and
replace them if necessary, see chapter Cleaning air filters
and fan.
The fan is running, but the device does not start:
The operating light flashes:
•
There might be no fuel in the tank. Check the filling level of
the tank. Refill fuel if the tank is empty (see chapter Filling
the tank).
•
The pump pressure might be incorrect. Check the pressure
at the pump and adjust it if necessary, see chapter
Adjusting the air pressure for the pump.
The fan does not start, even though the device is connected
and switched on:
The operating light flashes:
•
The thermostat setting might be too low. Turn up the