TL-3120 Motion Control User Manual
WWW.SZTROCEN.COM
84
Figure 1-2 Panasonic A5 Low Speed Pulse Wiring Diagram
PIN
3
4
5
6
Signal
PULSH1
PULSH2
SIGN1
SIGN2
Signal
DIR
PUL
DC 5V
PIN
3
2
1
Panasonic MINAS-A 50P
Interface
TL-3120 Servo Control
Interface
Table1-1 Panasonic A5 Series Basic Setting Parameters
Mode
Value
Instruction
Pr001
0
Control mode, must be set to position mode.
Pr007
3
Must be “Pulse + Direction” mode.
Pr005
1
High-speed pulse connection mode, the parameter is set to
“
1
”
, and the maximum pulse frequency is 3Mpps.
Low speed pulse connection mode, the parameter is set to
"0", and the maximum pulse frequency is 500Kpps.