Electric shower
8
Area to be
cut away
FITTING THE SHOWER TO THE WALL
Note:
The control knob is an integral part of the
cover – DO NOT attempt to remove it.
Unscrew the two top and one bottom retaining
screws
(fig.7)
and lift the cover from the
backplate. To access the pipe and cable
connections lift off the trimplate
(fig.8)
.
Entry positions for the mains water are from the
bottom or from the rear. Cable entry is via the
top or rear.
Note:
Deviations from the designated entry
points will invalidate product approvals.
If bottom surface entry is required for the mains
cold water, then the necessary opening will need
to be cut out in the trimplate
(fig.9)
.
Fig.7
Fig.9
Fig.8
WARNING!
Check there are no hidden cables or
pipes before drilling holes for wall
plugs. Use great care when using
power tools near water. The use of
a residual current device (RCD) is
recommended.