Electric shower
20
FAULT FINDING
Problem/Symptom Cause
Action/Cure
5.
Shower varies
from normal
temperature to
cold during use.
6.
Pressure relief
device has
operated (water
ejected from PRD
tube).
7
Shower fails to
shut off flow when
power selector
turned off and
isolated at main
switch.
4.4
Electrical malfunction
or safety cut-out has
operated.
5.1
Water pressure has
dropped below
minimum required.
6.1
Blocked showerhead.
6.2
Twisted/blocked
flexible shower hose.
6.3
Showerhead not
removed while
commissioning.
7.1
Debris in solenoid
valve.
4.4.1
Have unit checked by suitably qualified
electrician or contact Customer Service.
5.1.1
Wait until the water pressure resumes to
normal.
6.1.1
Clean sprayplate and then fit a new PRD.
6.2.1
Check for free passage through hose.
Replace hose if necessary and then fit new
PRD.
6.3.1
Fit new PRD. Commission unit with
showerhead removed.
7.1.1
Replace solenoid valve assembly.
Note:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please contact Triton Customer Service.
Do not remove the shower from the installation.