Electric shower
2
INTRODUCTION
This book contains all the necessary fitting and
operating instructions for your electric shower.
Please read them carefully.
The shower installation must be carried out by a
suitably qualified person and in the sequence of
this instruction book.
Care taken during the installation will provide a
long, trouble-free life from your shower.
SPECIFICATIONS
Electrical
Nominal power
Nominal power
rating at 240V
rating at 230V
8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)
9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)
Water
Inlet connection – 15 mm diameter.
Outlet connection – ½” BSP male thread.
Entry Points
Water –
Right:
bottom back, bottom.
Cable –
Right:
middle back, top.
Materials
Backplate, cover, controls, showerhead – ABS.
Sprayplate – Acetal.
Elements – Minerally insulated corrosion resistant
metal sheathing.
Dimensions
Height
−
309 mm
Width
−
212 mm
Depth
−
95 mm
Standards and Approvals
Splashproof rating IPX4.
Complies with the requirements of current British
and European safety standards for household
and similar electrical appliances.
Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European
Community Directives (CE).
ADVICE TO USERS
The following points will help you understand
how the shower operates:
a.
The electric heating elements operate at a
constant rate at your chosen power setting.
It is the rate of the water passing through
the heater can which determines the water
temperature. (The slower the flow, the hotter
the water becomes; the faster the flow, the
cooler the water).
b.
During winter the mains water supply will
be cooler than in the summer, so the flow
rate will vary between seasons at any one
temperature setting. At different times of the
year you may have to adjust the position of
the temperature control to maintain your
desired temperature setting.
c.
The stabiliser valve minimises variations in
shower temperature during mains water
pressure changes. If changes in shower
temperature are experienced during normal
use, it will most likely be caused by the
water pressure falling near to or below the
minimum level. The drop in pressure may
be due to water being drawn off at other
points in the house whilst the shower is in
use. If pressure drops appreciably below
the minimum, the heating elements will
automatically cut out.
If ever the water becomes too hot and you
cannot obtain cooler water, first check that
the sprayplate in the showerhead has not
become blocked.
DO NOT place items such as soap or shampoo
bottles on top of the unit. Liquid could seep
through the joint between the cover and
backplate, and possibly damage the sealing
rubber.
IMPORTANT:
When first installed the
unit will be empty. It is essential the
unit should contain water before the
elements are switched on. It is vital that
the commissioning procedure is followed.
Failure to carry out this operation will
result in damage to the unit and will
invalidate the guarantee.
Replacement parts can be ordered from Customer
Service. See
‘spare parts’