Fail Safe
(Fire Rating is void
when 4800F is fail-safe)
You should NOT see the "X" on top of the actuator cam.
Use the plunger and
RED colored solenoid
spring assembly.
Fail Secure
You should have the "X" mark on top of the actuator cam.
Use the plunger and
BLUE colored solenoid
spring assembly.
DO NOT OPEN
THIS SIDE.
TROUBLESHOOTING THE COMPLETED INSTALLATION:
.
Seat wires properly in
the housing channel so
the cover will seat flat.
INSTRUCTIONS FOR CHANGING THE THE 4800F FROM FAIL SECURE
TO FAIL SAFE:
To change the Fail Secure 4800F into a Fail Safe , open the
mechanism side of the strike (as shown on the right) by removing
the mechanism cover screws (3 places) and the cover. Lift the solenoid
and gently pull off the solenoid plunger and BLUE spring assembly
and replace it with the solenoid plunger and RED colored spring
assembly. Pull off the actuator cam, and replace it with the fail-safe cam.
Before closing the unit, make sure that the wires are properly seated
on the wire channel (see figure on right). Save the plunger and BLUE
colored spring assembly for future use.
For changing from Fail Safe to Fail Secure, just reverse the
above procedure
SYMPTOM: ELECTRIC RELEASE IS NOT ACTUATING:
1. Verify proper voltage is present AT STRIKE. If voltage is present: the strike may have been
affected during the installation, or dirt or debris may be preventing proper operation. Inspect
electric release and clean. NOTE: DO NOT LUBRICATE SOLENOID
2. If voltage IS NOT present:
A) Verify Circuit breaker is on, B) Verify voltage at the transformer/power supply output. C)
Verify that there are no additional, external switches or devices which may be interrupting your
circuit. D) Check for damaged wiring or bad wire splices.
SYMPTOM: STRIKE IS WORKING BUT WILL NOT OPEN:
1. Check for other locks on door
2. Check for proper lock-latch engagement
3. Check for excessive back pressure on door release latch by following these steps:
A) Push the door from the outside to try and relieve the bolt to latch pressure and actuate
the 4800F. B) While the 4800F is unlatched swing the door open. If the door opens, then the bolt
maybe applying pressure to the latch. Adjust the position of the 4800F to relieve the pressure.
POSSIBLE REMEDIES:
1. Re-adjust (or install) a door closer, Remove door silencers, Re-center electric release in jamb,
Remove or trim weather stripping around the door.
2.
Installing this strike on an uneven surface can cause problems with the internal mechanism of
this device. Specifically, it will cause localized mechanical pinching of the moving parts. Locate
where the pinching is occurring and level the frame surface at that location.
(FIG W)
4.
Uneven
Frame Soffit
Ideal Frame
Soffit Flatness
(FIG W)
PHONE: (203) 730-1756
FAX: (203) 730-1781
2 Parklawn Dr., Suite F
Bethel, CT 06801
email: [email protected]
website: www.trineonline.com
V. 16.0226
TRINE 4800F
THE FIRE RATED SOLUTION
FOR RIM PANIC EXIT DEVICES
4800F ELECTRICAL CHARACTERISTICS:
4800F
ELECTRIC
STRIKE
INSTALLATION INSTRUCTIONS
Congratulations on the purchase of this quality TRINE
security product. This product has been designed to
install easily, perform reliably, and provide years of trouble
free security.
BEFORE PROCEEDING with your installation, please review the
following list of features. If you have any questions after reading
this document please call TRINE's TECHNICAL SUPPORT
(203) 730-1756
, or visit us online @
trineonline.com
Built-in Electronics: The 4800F automaticallys allows
12-24AC & DC power, plus surge and kickback protection.
There are no external ‘pacs’ to use or install.
The 4800F is WH recognized for:
Class A, 3 Hour Single door / frame configuration
- UL10C, Fire Tests of Door Assemblies
- UBC 7-2, Uniform building Code
- CAN4 S104, Standard Method for Fire Tests of Door
Assemblies NFPA 252
Issue: 1999/01/01 Standard Methods of Fire Tests of Door
Assemblies
NOTE: WH fire listing is void when using fail safe action.
BHMA Grade 1 Electric Strike
9"
1 3/4"
8 1/4"
1 1/2"
1/8"
3/4"
7/8"
Pull-in/Hold
Amps (A)
Duty
Voltage
Sound
12DC
.566 A/.217 A
Intm/Cont. Silent
24DC
.253 A/.099 A
Intm/Cont. Silent
12AC
@ 50-60Hz
.509 A/.181 A
Intm/Cont. Silent
16AC
@ 50-60Hz
.405 A/.149 A
Intm/Cont. Silent
24AC
@ 50-60Hz
.215 A/.087 A
Intm/Cont. Silent
OPERATING TEMP RANGE: -
20°C TO +65°C
DO NOT APPLY AN OVER VOLTAGE OF MORE THAN 10%
OVER THE RATED OPERATING VOLTAGE OF THE
STRIKE OR THE SOLENOID WILL BE DAMAGED.
2 Parklawn Drive l Suite F l Bethel l Connecticut l 06801
TO 120V
AC LINE
USE 12V THRU 24V
AC OR DC
TRANSFORMER
WIRING FOR
FAIL-SECURE MODE
SWITCH
NORMALLY
OPEN
FAIL-SECURE
CONFIGURED
STRIKE
OPTIONAL BUZZER
NOTE: MATCH THE VOLTAGE
OF THE TRANSFORMER
AND IF REQUIRED,
OBSERVE POLARITY
USE 12V THRU 24V
AC OR DC
TRANSFORMER
TO 120V
AC LINE
WIRING FOR
FAIL-SAFE MODE
SWITCH
NORMALLY
CLOSED
FAIL-SAFE
CONFIGURED
STRIKE
USE 12V THRU 24V
AC OR DC
TRANSFORMER
TO 120V
AC LINE
WIRING FOR
FAIL-SAFE MODE
WITH OPTIONAL BUZZER
SWITCH
SINGLE POLE
DOUBLE THROW
FAIL-SAFE
CONFIGURED
STRIKE
OPTIONAL BUZZER
NOTE: MATCH THE VOLTAGE
OF THE TRANSFORMER
AND IF REQUIRED,
OBSERVE POLARITY
RECOMMENDED PREINSTALLATION CHECK FOR THE 4800F SURFACE
MOUNT STRIKE:
1. Determine that door is properly adjusted; Door must operate properly in order for
system to provide best results.
2. Door must swing properly, without interfering with jamb or sill
3. The door should be equipped with a door closer and the door closer "latch
mode" must hold door in a completely closed position in order to avoid the lock
latch from applying pressure against the releasing latch portion of the electric
strike.
4. Electrical wire connections must be completed and ready to be terminated
inside the frame.
5. Confirm that the power line in the frame is the correct voltage, amperage, and
that the switch works properly.
6. Confirm proper clearance exists between the end of the lock latch and jamb.
7. The electric door strike must be aligned properly with lock latch when it is
installed on the doorjamb.
8. For best installation results, the door frame must be reasonably flat and straight.
2.
3.
WHAT IS INCLUDED IN THE 4800F BOX:
INCLUDED IN THE BOX ARE:
1 - (1) 4800 OR 4801 SURFACE MOUNTED STRIKE
2 - (2) 1/4-20 x 1" UH CAP SOCKET MOUNTING SCREWS
3 - (4) ANCHOR SYSTEM PINS
4 - (1) QUICK CONNECT SOCKET AND WIRE ASSEMBLY
5 - (2) SEALED CRIMP CONNECTORS
6 - (1) FAIL SAFE SPRING (RED COLORED) & SOLENOID PLUNGER
7 - (1) FAIL SAFE CAM
(NOTE: NOT FIRE RATED WHEN CONFIGURED FAIL-SAFE)
8 - (1) 1/8" THICK SPACER PLATE/ FRAME MOUNTING TEMPLATE
1
7
3
8
4
2
5
6
RECOMMENDED
TOOLS:
- 3/32 inch Allen Wrench
- 3/16 inch Allen Wrench
- 3/4 inch diameter Drill Bit
- #7 (0.201 inch
diameter) Drill Bit
- #30 (0.128 inch
diameter) Drill Bit
(for the optional Anchor Pins)
- 1/4-20 Tap
- Drill
- Marker
Figure 3
Figure 6
Figure 1
With the door closed,
mark the position of
the bolt on the frame.
Figure 2
Position the 4800F on
the frame and mark
the desire position.
Figure 4
Use the spacer as
template to mark the
holes you desire to use.
Push the anchor pins in
the back of any 4800F
series strike if you
desire to use this
Figure 5
Crimp the quick
connect socket
assembly to the
power wires.
Crimp Connectors
Quick Connect
Socket
Assembly
Power Wire
1. Mark the end position of the exit devices latchbolt on the doorframe.
(Take off the original strike if present). See Figure 1.
2. Using the marks you just made as your guide, position the 4800F
over the mark on the frame. Make sure that the Auxiliary latch rides
up properly over the 4800's edge, and is engaged, and that the door
is in the fully closed position. See Figure 2
3. When you are confident with the position of the 4800F, mark two
perpendicular edges of the 4800F on the frame See Figure 3
4. Put the 4800F aside for a moment and place the spacer supplied
with the 4800F inside the marks you just made on the frame.
5. Using the spacer as a template; mark the two mounting holes and
the wire exit hole. If you are using the optional anchor pins, mark the
anchor pin positions using the spacer as a template. See Figure 4
6. Using a #7 bit, drill the two mounting holes and tap them ¼-20.
7. Using a ¾ inch diameter bit, drill the power wire exit hole
8. If you are utilizing the anchor pin system, use a #30 bit, drill the four
anchor pin holes.
9. Deburr any sharp edges around the holes after drilling, so that the
4800F will rest on a smooth clean surface and the wires will not be
accidentally cut or damaged while installing.
10. Pull the power wiring down the door frame and through the ¾ inch
diameter power wire hole.
11. Using the provided sealed crimp connectors, terminate the quick
connect socket assembly to the power wires. See Figure 5 (NOTE:
The 4800F is not polarized)
12. If you intend to use the anchor pins system, insert them into the four
holes on the back side of the 4800F. See Figure 6. If you also intend to
use the 1/8" thick spacer plate, you can now slip the plate over the pins.
13. Snap together the power supply side connector coming off the
frame to the 4800 connector. Carefully push the wires and
connectors back into the frame.
14. Using the 2 mounting screws, mount the 4800F strike to the frame.
15. Adjust the strike to the desired position and tighten the mounting
screws using the 3/16 inch Allen wrench.
16. Using the 3/32 inch Allen wrench turn the two setscrews on the side
of the 4800F until they support the strike. DO NOT over tighten the
setscrews.
17. Turn the power ON and test your installation. Installation is now
complete.
INSTALLATION PROCEDURE:
CAUTION: TO AVOID ELECTRICAL SHOCK AND INJURIES,
BEFORE DOING YOUR WIRING, TURN OFF THE POWER FROM
THE CIRCUIT BREAKER.
CHECK OUT THE VIDEO ON
SEARCH
“4850ITL”
USE THE 4850ITL TO QUICKLY
MARK, TEST, ADJUST, CENTER
PUNCH AND SKIP MOST OF
THESE STEPS!
more info @ trineonline.com/4850itl.php