017TDC-2 & 3 TRIGGER TIME DELAY SETTING
:
The 017TDC receiver trigger time delay can be adjusted to stay "ON" for 5
seconds minimum to 30 seconds maximum. Turn the time delay knob/knobs to
your desired setting. Counter-clockwise to reduce the delay, Clockwise to
increase delay. For the location of the knobs, see Figure 10 below.
SECURITY CODE SETTING
:
Once all the electrical connections had been made and checked, you
have to set the security codes for the 017TDC-2 or 3 receiver and the
018-2 transmitter. If you have the 017TDC-3 you have to set the
switching mode of the two relays.
The security code positions for the receiver must match the codes of the
transmitter/ transmitters for these devices to communicate properly.
To change the codes on the 017TDC-2 or 3 receiver, open the cover and
set the Security Code tri-state DIP switches to your desired positions,
open the 018-2 transmitter and match the coding of the receiver. Figure 8
shows the location of the DIP switches for the receiver and the 018-2
transmitter.
SECURITY
CODE SWITCHES
FIGURE 8
EXAMPLE CODE SETTING:
MUST BE
THE SAME
SWITCH COMBINATION
FIGURE 9
FIGURE 10
TIME DELAY
KNOBS
017TDC-2
017TDC-3
3
Optionally, you can connect two fail-safe strikes on the 017TDC-3 that can have
two switches to manually override the wireless receiver. Refer to the schematic
shown in Figure 7 below.
This application is not limited to fail-safe strikes only. Any normally "ON" devices
that needs to be temporarily switched "OFF" can substitute for fail-safe strikes
for example Magnetic Locks.
NOTE:
If external push button switches were used, the time delay function of
the receiver is overridden when using the push buttons so the load will stay
"ON" only for the duration that the switches are pressed.
CONNECTING TWO FAIL-SAFE STRIKES
AND SWITCHES TO YOUR 017TDC-3
Fail-Safe
Strike #1
Fail-Safe
Strike #2
FIGURE 7
TRANSFORMER
+
(For DC ONLY)
-
(For DC ONLY)
-
(For DC ONLY)
-
(For DC
ONLY)
Power Supply
12 - 30 V AC/DC
USE THE COPPER SHUNT (INCLUDED) TO SUPPLY (-) POWER
TO THE STRIKE BY CONNECTING (-) TO COM1 & COM2
SWITCH
#2
SWITCH
#1
USE NORMALLY
CLOSED
SWITCHES
IN
+
-
COM1 COM2
NO1
NC1
NO2
NC2
SETTING: SECURITY CODE, TIME DELAY AND SWITCHING MODE