Figure 8.
Figure 9.
Take Latch Pivot Shaft with crown
end in upright position and insert
through shaft hole at the top of
the frame. This will push the
Assembly Pin out through bottom
hole.
Check Slider action. Make sure Slider
is free to move up and down with no
resistance.
Before replacing cover, make sure the
unit operates properly by testing with
appropriate voltage. NOTE: Do not
attempt to lubricate Electric Strike!!!
Place Strike face down and attach the
cover over the Coil with wire leads
seated through the notched hole.
5. Splice Electric Strike wiring to power wiring and secure with
wire nuts supplied.
6. Install Electric Strike into door jamb and secure with Screws
supplied into the Strike Face Plate..
7. Verify that door operates correctly when Electric Strike is
energized and not energized.
Insert
Latch Pin
Screw
(6)
Slider must rest inside of
Coil Assembly Bracket
NOTE
1. Rectifier can be located either between transformer and push button or
between push button and Electric Strike.
2. Use a current-regulating rectifier (CR-1) for converting AC voltage at the
transformer secondary to DC for operating a DC Electric Strike.
3. AC units should not be operated at continuous duty.
4. Improperly installed or misused units are not covered by manufacturer’s
warranty.
5. In UL listed systems, a UL listed burglar alarm power supply and annuncia-
tor of compatible rating should be employed.
ELECTRICAL CHARACTERISTICS CHART
FAIL SECURE(Intermittent Duty) NORMALLY LOCKED
VOLTAGE CURRENT/AMPS OHMS SOUND DUTY
12 VAC
.70
4.5
Buzz Intm
24 VAC
.37
18.0
Buzz Intm
12 VDC
.28
43.0
Silent
Intm/Cont
24 VDC
.15
64.0
Silent
Intm/Cont
TOTAL WIRING
LENGTH TO
TRANSFORMER
12V
24V
Up to 50 ft
18 AWG 20 AWG
50 to 150 ft
16 AWG 18 AWG
150 to 300 ft 14 AWG 16 AWG
300 to 600 ft 12 AWG 14 AWG
INSTALLATION PROCEDURE
For new or replacement installation:
1. Verify that voltage rating of Electric Strike is compatible
with voltage supply at installation. Coil assembles are wire
lead color coded for voltage as shown:
WIRE LEAD
CODE/STRIPE
12AC
Blue/Orange Stripe
12DC
2 Orange Stripe
24AC
Blue/Black Stripe
24DC
2 Black Stripe
2. Using dimensions of template supplied with Electric Strike,
mark door frame for cutout and screw holes.
3. Prepare door jamb (cut out frame if required) for Electric
Strike. Leave sufficient wire length or splicing between power
wiring and Electric Strike wire leads.
4. If required, run new wiring to door frame mounting
hole. See Figure 10 for typical wiring installations. Refer to
wiring chart below for correct wire size. (Total wiring length
includes routing to door-release push button.)
NOTE
For DC operation, to obtain an audible signal when
Electric Strike is energized, install buzzer type BZ-12 for
12 VDC operation, or BZ-24 for 24 VDC operation
(purchased separately), as illustratd in Figure 10. DC
buzzer must be wired in parallel.
110-120 VAC House Current
Primary Side (Input)
Transformer (Stepdown)
BZ 12 or BZ24
Buzzer (Optional)
Secondary Side (Output)
See Notes
Rectifier
Rectifier
Figure 10.
Typical Electric Strike Wiring