EN 430/435 LBSM WIRING SCHEMATIC
FIVE WIRE SCHEMATIC UTILIZING ONE TRANSFORMER
This wiring arrangement uses the least amount of conductors between the Panel and the Frame.
FRAME SIDE
WIRING
120
VAC
12VDC
OUTPUT
CONTROL SWITCH
OR RELAY
SWITCHED POWER
PANEL INDICATOR
OR OTHER
SIGNALING DEVICE
POWER
TRANS-
FORMER
CONTROL
PANEL
PANEL SIDE
WIRING
Hook-up to either Normally Open
or Normally Closed Terminal
Hook-up to either Normally Open
or Normally Closed Terminal
WHITE - NORMALLY CLOSED (NC)
BLACK -
RED +
BLUE COMMON (COM)
YELLOW - NORMALLY OPEN (NO)
GRAY - NORMALLY CLOSED (NC)
GREEN COMMON (COM)
ORANGE - NORMALLY OPEN (NO)
POWER TO STRIKE
POWER TO STRIKE
LB MODULE
CONSTANT
POWER
1440 Ferris Place
Bronx
New York
10461
SIX WIRE SCHEMATIC UTILIZING TWO TRANSFORMERS
This wiring arrangement is used to isolate the strike operation, from the LB and/or the SLIDER sensor and
power board and the Panel Indicator or Signaling Device.
SWITCHED POWER
CONSTANT POWER
WHITE - NORMALLY CLOSED (NC)
BLACK -
RED +
BLUE COMMON (COM)
YELLOW - NORMALLY OPEN (NO)
GRAY - NORMALLY CLOSED (NC)
GREEN COMMON (COM)
ORANGE - NORMALLY OPEN (NO)
POWER TO STRIKE
POWER TO STRIKE
120
VAC
12 - 24 VDC
OUTPUT
12 - 24 VDC
OUTPUT
CONTROL SWITCH
OR RELAY
PANEL INDICATOR
OR OTHER
SIGNALING DEVICE
POWER
SUPPLY 1
120
VAC
POWER
SUPPLY 1
PANEL SIDE
WIRING
FRAME SIDE
WIRING
CONTROL
PANEL
Hook-up to either Normally Open
or Normally Closed Terminal
Hook-up to either Normally Open
or Normally Closed Terminal
LB MODULE
WIRING SCHEMATICS FOR DIFFERENT APPLICATIONS
Summary of Contents for 4100 Electric Strike
Page 25: ......