TRINE 4100
THE ONE BOX SOLUTION
FOR CYLINDRICAL AND MORTISE LOCKS
Congratulations on the purchase of this quality TRINE security
product. This product has been designed to install easily,
perform reliably, and provide years of trouble free security.
BEFORE PROCEEDING
with your installation, please review the
following list of features. If you have any questions after reading
this document please call TRINE's TECHNICAL SUPPORT
(718)
829-2332 EXT. 447
, or visit the TRINE Web site at
www.trineonline.com
1440 Ferris Place l Bronx l New York l 10461
4100
ELECTRIC
STRIKE
INSTALLATION INSTRUCTIONS
CC Faceplate
(centered opening)
The 4100 is WH recognized for:
Class A, 3 Hour Single door / frame configuration
- UL10C, Fire Tests of Door Assemblies
- UBC 7-2, Uniform building Code
- CAN4 S104, Standard Method for Fire Tests of Door Assemblies
NFPA 252 -
Issue: 1999/01/01 Standard Methods of Fire Tests of Door Assemblies
NOTE: WH fire listing is void when using fail safe action.
ANSI/BHMA A156.5 - 1992 - 4-7/8" x 1-1/4" Fits
Cutout Specification A115.1 (with Slight Jamb Modification)
BHMA - Grade 1
TROUBLESHOOTING THE COMPLETED INSTALLATION:
WIRING DIAGRAMS
DO NOT APPLY AN OVER VOLTAGE OF MORE THAN 10%
OVER THE RATED OPERATING VOLTAGE OF THE STRIKE OR
THE SOLENOID WILL BE DAMAGED
SYMPTOM: Electric release is not actuating:
1. Verify proper voltage is present AT THE STRIKE. If voltage is
present, the strike may have been affected during the
installation, or dirt or debris may be preventing proper
operation. Ensure that all moving parts are clean. DO NOT
LUBRICATE THE SOLENOID.
2. If voltage IS NOT present:
· Verify Circuit breaker is on
· Verify voltage at the transformer/power supply output.
· Verify that there are no additional, external switches or
devices which may be interrupting your circuit.
· Check for damaged wiring or bad wire splices.
SYMPTOM: Door will not open but strike is working
· First, check to see if the electric strike works properly
while the door is open.
· Check for proper lock-latch engagement
· Check for pressure from the door on the electric strike
by following these steps:
Push the door from the outside, try and relieve the bolt
to latch pressure and actuate the 4100. While the
4100 is unlatched swing the door open. If the door
opens, then the bolt maybe applying pressure to the
latch. Adjust the position of the 4100 to relieve the
pressure.
Possible remedies include:
1. Re-adjust door closer.
2. Remove door silencers.
3. Remove, or trim, weather stripping around the door.
4. Adjust electric strike position if possible.
5. Correct excessive warping of door.
USING THE LATCH SPACER SHIMS (CONTINUED...)
For locks not aligning to the vertical center of the strike, mount
the shims as shown below. Most if not all mortise locks will
work with the latch shims mounted this way.
Mount the shims with the
steps positioned away from
the top of the latch like this.
Auxilliary
Deadlocking Trigger
PHONE: (718) 829-2332
FAX: (718) 829-6405
1440 FERRIS PLACE
BRONX, NY 10461
email: [email protected]
website: www.trineonline.com
4
Current
Power
Voltage Draw Consumption Resistance
12DC
.240 A
2.90 W
50 Ω
24DC
.114 A
2.74 W
210 Ω
12AC
@ 50-60Hz
.210 A
2.50 W
50 Ω
16AC
@ 50-60Hz
.281 A
4.48 W
50 Ω
24AC
@ 50-60Hz
.420 A
10.08 W
50 Ω
4100 ELECTRICAL CHARACTERISTICS:
4 7/8"
4 1/8"
1 3/4"
1/4"
25/32"
1 1/4"
3/4" CAVITY DEPTH
1 5/8"
3 3/8"
1 3/8"
Mount the shims with the steps
positioned aligned with the top
of the latch like this.
This position will ensure that the cylindrical
lock's auxilliary trigger will function properly.
USING THE LATCH SPACER SHIMS
The latch spacer shims are used to make adjustments to
minimize the space between the door's inside face and the
door stop or reduce door play. For cylindrical locks aligning to
the vertical center of the strike mount
the shims as shown below.
Auxilliary Trigger
OPERATING TEMP RANGE: -
20°C TO +40°C
DO NOT APPLY AN OVER VOLTAGE OF MORE THAN 10%
OVER THE RATED OPERATING VOLTAGE OF THE
STRIKE OR THE SOLENOID WILL BE DAMAGED.
When removing the connector and using the wires direct;
Red & Blue Wire accepts 12DC & 12-16 AC,
Brown & Blue Wire accepts 24DC.
24V DC OR 12V DC
TRANSFORMER
TO 120V AC LINE
PUSH
BUTTON
NORMALLY
CLOSED
+
-
FAIL-SAFE
ELECTRIC STRIKE
USE THE PROPER
CONNECTOR 12VDC OR 24VDC
ASSEMBLY FOR
THE 4100 STRIKE
Cannot use AC in Fail Safe Configuration
24V DC OR 12V DC TRANSFORMER
TO 120V AC LINE
PUSH
BUTTON
NORMALLY OPEN
+
-
USE THE PROPER
CONNECTOR 12VDC OR 24VDC
ASSEMBLY FOR
THE 4100 STRIKE
For AC use the 12 VDC connectors
For 12 - 24 VAC use 50-60 Hz
FAIL-SECURE
ELECTRIC STRIKE
V. 14.0814
FACEPLATE AND OFFSET DIMENSIONS:
CAVITY
C L
STRIKE
C L
1 1/64"
1 11/32"
CAVITY
C L
STRIKE
C L
29/32"
1 11/32"
STRIKE
C L
CAVITY
C L
19/32"
1 15/32"
MHO
MMO
MLO
1 - (1) 4100 Electric
Strike Mechanism
2 - (4) Faceplates with Openings (CC, MHO, MMO, MLO)
3 - (2) #12-40 x 1 inch Philips Mounting Screws
4 - (2) #12-40 x 1 inch Torx
®
Security Mounting Screws
5 - (2) Quick Connect Socket &
Wire Assembly 12VDC
& 24VDC Version
6 - (2) Sealed Crimp
Connectors
7 - (2) Latch Spacer
Shims & (2) Mounting Screws
8 - (1) Frame Trim Skirt & (2) Screws
WHAT'S IN THE BOX:
4100 OPTIONS:
4100RS -
FAIL SAFE CONFIGURATION
4100LB -
LATCH BOLT MONITORING
4100RSLB -
FAIL SAFE/LATCH
BOLT MONITORING
BZ-12
- 12VDC Piezo Buzzer
BZ-24
- 24VDC Piezo Buzzer