WSP™
DATA SHEET
WSP™ SELF-PRIMER PUMPS
WSP-D300_10
Rev. 3
01/09/20
© 2019 The Factory
56
AFTER THE PUMP CASING HAS BEEN FILLED, REINSTALL AND TIGHTEN THE FILL
PLUG. FAILURE TO OPERATE THE PUMP WITHOUT ALL CONNECTION PIPING
SECURELY INSTALLED COULD CAUSE LIQUID IN THE PUMP TO BE FORCED OUT
UNDER PRESSURE AND MAY RESULT IN INJURY.
When filling your pump, take off the fill cover on the pump casing or pull the
fill plug at the case top. Fill the casing with clean liquid until full. Be sure to
replace the fill cover or plug before the pump is used.
B. START-UP
Follow instructions in the Operation Manual that came with the power source.
1. Rotation
When facing the impeller, the pump’s proper rotation direction is
counterclockwise. Incorrect pump rotation may harm the pump and seriously
impact performance. Be sure to inspect the power source direction of
rotation prior to using other troubleshooting procedures if your pump’s
performance is not within the manufacturer’s specified limits (See Pump
Performance Curve in Section X).
When an electric motor is running the WSP™ Self-primer pump, remember to
remove the V-belts and couplings. If the V-belts and couplings are not
removed, you must disconnect the pump from the motor and only then check
the motor’s rotation. Be sure to watch the direction of the motor shaft or the
cooling fan while the motor is operating.
Use a qualified electrician to swap out any two of the 3-phase wires to alter
the direction of rotation when the rotation on a 3-phase motor is incorrect.
Review the documentation that came with the motor for particular instructions
from the manufacturer when a single-phase motor rotation is incorrect.
C. OPERATION
1. Lines with a Bypass
The valve will automatically open to allow pump priming and automatically
close once priming is finished when a WSP™ ARV is installed. See Section
VIII, INSTALLATION, Part G, WSP™ ARV Theory of Operation.
Summary of Contents for 10-WSP
Page 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 64 ...
Page 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 66 ...
Page 67: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 67 ...
Page 68: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 68 ...
Page 69: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 69 ...
Page 70: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 70 ...