Cable Type
Manufacturer Part
Number
RJ45 Connector Type
Manufacturer Part
Number
CAT 5E UTP Solid, 24
AWG Cable
DC-5E8-RD-1K-L Pan
Pacific
CAT 5E UTP RJ45
Connectors, for Solid
Cable
CN150-45-1
Mfg: Abergetty
Supplied by:
CAT 5E, STP Solid,
24AWG Cable
10X6-521TH
CAT 5E STP RJ45
Connectors, for Solid
Cable
SW-22350
CAT 5E, STP Stranded,
24AWG Cable
10X6-521SH
CAT 5E STP RJ45
Connectors, for Stranded
CN150-45-11
Mfg: Abergetty
Supplied by:
CAT 6, UTP Stranded
Cable
10X8-071SH
CAT 6 UTP RJ45
Connectors, for Stranded
Cable
SW-22346
CAT 6, UTP Solid Cable
10X8-081TH
CAT 6 UTP RJ45
Connectors, for Solid
Cable
CN150-45-4
Mfg: Abergetty
Supplied by:
CAT 6 STP Solid
10X8-591NH
CAT 6 STP RJ45
Connectors, for Solid
Cable
CN150-45-10
Mfg: Abergetty
Supplied by:
Note:
It is very important that connectors be specified for the cable being used. As an
example, if using Cat5e solid conductor cable, the connectors should be specified for
Cat5e solid conductor cable. Some connectors are specified for both solid and
stranded conductors Always use an RJ45 crimping tool that is specified for use with
the connectors being used.
During the installation of the Ethernet cable, a pulling force of 25 pounds should not be
exceeded. The bending radius of the cable should never be less than four times its diameter.
Ethernet cable should not be deformed by tightly cinched cable ties.
Shielded Ethernet cable may be required in cases where the cable is installed in close proximity
to equipment or conductors generating strong electromagnetic fields. In this case follow Shielded
Twisted Pair (STP) installation guidelines.