Ethernet communicator E16T
In “Reporting” window settings for „Primary“ channel:
3)
Enable
– enable primary communication channel.
4)
Remote Host
– enter the receiver’s IP address.
5)
Remote Port
– enter receiver’s network port number.
6)
TCP or UDP
– choose event transmission protocol (
TCP
or
UDP
) in which events should be sent.
7)
PING Time
– PING signal transmission period.
8)
Encryption key
– enter the encryption key that is set in the receiver.
9)
(Recommended) Configure the
Backup
Channel Settings.
10)
TCP protocol
– select which encoding protocol will be use: TRK (for TRIKDIS receivers), DC-09_2007
or DC-09_2012 (for universal receivers).
11)
Encription enabled
- if TCP protocol SIA DC09_2012 is selected, encryption can be enabled.
12)
DC-09 encryption key
– enter encryption key that is set in the receiver.
13)
DC-09 receiver No.
- enter receiver number.
14)
DC-09 line No
. – enter receiver line number.
If you have selected DC-09 message transmission encoding, in addition to the “Reporting” window, on the
“Settings” tab, enter the object, line and receiver numbers