Ethernet communicator E16T
7.2
“System settings” window
“General” settings group
Account number
– if the events will be sent to the CMS (Central Monitoring Station), enter the
account number provided by the CMS (4 characters hexadecimal number, 0-9, A-F).
Use security panel account ID
– if the checkbox is selected, the communicator will send events with
the account ID entered in the panel instead of the value set in the
Account number
field.
Test period -
periodic test messages will be sent according to a time interval set in this section.
Security panel model
– enable/disable DTMF landline interface on the communicator.
„Ethernet settings” settings group
Internal MAC -
unique communicator identifier code.
Select
Use DHCP
checkbox for communicator to register automatically to the network.
o
If automatic registration is unsuccessful, enter
Internal IP address
, subnet
Mask
,
Gateway
address
and
DNS
service manually.
„Access“ settings group
There are two access levels (administrator and installer) when configuring the
E16T
communicator:
Administrator code
- allows full access to the configuration (default code – 123456).
Installer code
- allows limited access for installer to the configuration (default code - 654321).
Allow installer to change
– the administrator can specify which settings the installer can change.
o
Account number;
o
Reporting;
o
Ethernet settings;
o
Event summary.
Note: