www.trikdis.com
20
March, 2019
Ethernet communicator E16T
7.4
„Event Summary“ windows
This window allows you to enable, disable, and change internal messages and input messages from the
device. Turning off the internal message in this window will not send it regardless of other settings.
Additional sensors can be connected to the communicator inputs. When the sensor is triggered, the
communicator sends an event notification. The login is assigned a Contact ID code, which will be sent to
the CMS and
Protegus
.
The event Contact ID codes that will be sent to the CMS and to the
Protegus
, when the event occurs will
be indicated by ticking the checkbox.
„Input description“ settings group
Partition
– enter the partition number.
Contact ID
– enter the event code or leave the default value. Upon entering the event, the event
code will be sent to Protegus and CMS.
Zone No. –
enter the zone number and it will be sent in messages.
Type
– select input types (NO, NC, EOL).
Enable / Alarm
– select
Alarm
to receive report when event occurs.
Enable / Restore
– select
Restore
to receive report when input line will restore.
„Internal event description“ settings group
En
– checked event fields where messages will be sent to CMS and
Protegus
.
E/R
– choose what type of event will be sent when input is triggered –
Event
or
Restore
.
Contact ID
- enter the event code or leave the default value. Upon entering the event, the event code
will be sent to
Protegus
and CMS.
Partition
– enter the partition (area) number that will be sent when an internal event occurs and the
system is restored.
Zone
– enter the zone number that will be sent when an internal event occurs and the system is
restored.