www.trikdis.com
18
March, 2019
Ethernet communicator E16T
„Output“ settings group
•
OUT type
- choose output operation type from list (Disabled, LAN OK, Communication Trouble,
Remote Control)
.
•
Inverted
- select checkbox if output function should be inverted.
•
OUT mode:
o
Pulse -
a status will take time as indicated in
Pulse Time
(pulse period in seconds) field.
o
Level -
a status will change and remain the same until the next command.
Pulse time
– enter time the duration of the pulse, s.. OUT output will be triggered for the set time
when the output mode is Pulse.
7.3
„Reporting“ windows
„CMS Reporting“ tab
The communicator sends messages to the monitoring station via a wired internet (IP) connection.
Messages can be sent via the primary or backup channel. The backup communication channel will be used
when the primary communication channel is interrupted.
Messages to the monitoring station are transmitted with encryption and password protection. To receive
and transmit messages to the monitoring program, a TRIKDIS receiver is required:
For connection over IP – software receiver IPcom Windows/Linux, hardware IP/SMS receiver RL14 or
multichannel receiver RM14.
„Primary“ settings group
Enable
– if the checkbox is selected, the main channel for sending event messages to the CMS (central
monitoring station) is activated.
Remote Host
– enter the domain or IP address of the receiver.
Remote Port
– enter the network port number of the receiver.
TCP or UDP
– select in which protocol (TCP or UDP) the events should be sent.