In order for the security panel to send events via the telephone communicator, it must be enabled and
properly configured. Set the control panel telephone communicator according to the programming guide
of security panel:
1)
Turn on the panel’s PSTN landline dialer.
2)
If the communicator is connected to the telephone line, enter the phone number - 1234. If the
communicator is connected to the control panel RING / TIP terminal, enter any number of at least 2
digits.
3)
Choose DTMF mode.
4)
Select Contact ID communication protocol.
5)
Enter the panel’s 4 digit account number.
4.1
Programming Honeywell Vista landline dialer
Using the control panel’s keypad enter these sections and set them as described:
*41 – enter monitoring station receiver telephone number;
*43 – enter control panel’s account number;
*47 – set the Tone dial to [1] and enter the number of dial attempts;
*48 – use default setting, *48 must be set to 77;
*49 – Split/Dual message. *49 must be set to 5;
*50 – delay for sending burglary alarm events (optional). Default value is [2,0]. With it the event
message transmission will be delayed for 30 seconds. If you want the message to be sent
immediately, set [0,0].
Exit programming mode
When all required settings are set, it is necessary to exit programming mode. Enter *99 in keypad.
4.1.1
Special settings for Honeywell Vista 48 panel
If you want to use
E16T
communicator with Honeywell Vista 48 panel, set the following sections as
described:
Section
Data
Section
Data
Section
Data
*41
1111 (receiver telephone
number)
*60
1
*69
1
*42
1111
*61
1
*70
1
*43
1234 (panel account
number)
*62
1
*71
1
*44
1234
*63
1
*72
1