4.

 

Dispose of remaining oil in the filter and the used filter in accordance to local 

environmental laws and practices. 

5.

 

Remove the old gasket from the filter head and wipe excess oil residue from the head. 

6.

 

Remove the new filter from its packaging and insert the new gasket provided with the 

filer into the gasket groove of the head. 

7.

 

Thread the new filter onto the head turning it counterclockwise and hand tighten. 

8.

 

Using the strap wrench, place the strap near the top of the filter to prevent collapsing 

and turn the filter ¼ turn to tighten. 

9.

 

Place the motor back on the pump and turn on. 

10.

 

Dispense fluid from the nozzle and observe the filter gasket checking for leaks. 

11.

 

If the leaking is noticed around the filer gasket, tighten the filter another ¼ turn with the 

strap wrench and repeat the procedure. 

 

Replacement Part 

Part Number 

Particulate Filter - 3 Micron Microglass Spin On Beta > 200 Absolute 

36972 

Particulate Filter - 10 Micron Microglass Spin On Beta > 200 Absolute 

36973 

Particulate Filter - 20 Micron Microglass Spin On Beta > 200 Absolute 

36974 

Water Filter - 10 Micron Nominal Spin On

 

36975

 

Water Filter - 25 Micron Microglass Spin On Beta > 200 Absolute 

36995 

 

 

 

Summary of Contents for 30035

Page 1: ...1235 Hickory Street Pewaukee WI 53072 For Customer Support 800 558 7008 61433 Drum Pump Filtration Unit Part 30035 Patent Pending Setup and Operating Instructions Rev C October 2020 ...

Page 2: ...igns Only one motor is needed and can be interchanged with multiple drum pumps 30018 Drum Pump Electric Motor 1 1Hp 110 120V 50 60 Hz 30021 Drum Pump Electric Motor 1 1Hp 220 230V 50 60 Hz 30019 Drum Pump Pneumatic Motor 3 4 HP INCLUDED COMPONENTS Remove the Drum Pump components from the shipping container and inspect components for any signs of damage Included Components 1 LV Drum pump assembly 1...

Page 3: ...rotection Code 77 for proper grounding and bonding procedures It is the responsibility of the operator to properly inspect and ground equipment before use DRUM PUMP ASSEMBLY 1 Place LV drum pump assembly on a worktable long enough to support the entire unit 2 Thread the Motor Drive Coupler onto the shaft and hand tighten 3 Place 3 Retaining Clip over the top of the LV drum pump assembly and slide ...

Page 4: ... hose onto the elbow connector and tighten Figure 2 12 Place the filter gasket onto the groove on the filter head 13 Thread the filter onto the head and hand tighten 14 Use a strap wrench place it at the top of the filter and tighten the filter turn to seat the gasket 15 Assemble the short grounding lead with clamp to the Drum pump side ensuring the fastener is securely tightened 16 Use the additi...

Page 5: ...und the filter gasket for leaks If the filter is leaking stop the unit and tighten an additional turn 11 To stop the flow release the nozzle hand trigger and then turn the motor off WHEN TO CHANGE THE FILTER AND PROCEDURE The filter head is outfitted with two pressure gauges The first gauge nearest to the pump indicates the pressure being produced by the pump The second gauge near the hose indicat...

Page 6: ...ace the strap near the top of the filter to prevent collapsing and turn the filter turn to tighten 9 Place the motor back on the pump and turn on 10 Dispense fluid from the nozzle and observe the filter gasket checking for leaks 11 If the leaking is noticed around the filer gasket tighten the filter another turn with the strap wrench and repeat the procedure Replacement Part Part Number Particulat...

Page 7: ...ver between the tangs on the foot bottom and turning the foot clockwise to remove it from the pump tube Note Foot threads are left handed threads 3 Place vise grips on the drive shaft above the impeller to hold the shaft while removing the motor drive coupler 4 Use a plyers on the motor coupler and turn clockwise to remove from drive shaft 5 Thread the new coupler P N 10412 onto the shaft and hand...

Page 8: ...sity 1 250 cSt 5 500 SUS Min Flow rate 1 250 cSt 1 75 GPM Average flow rates at room temp 70 F 21 1 C with 10 micron particle filter ISO 68 188 cSt ISO 100 302 cSt ISO 220 797 cSt ISO 320 1250 cSt Electric Pump 30018 7 25 GPM 5 75 GPM 2 25 GPM 1 75 GPM Pneumatic Pump 30019 6 0 GPM 5 25 GPM 1 75 GPM 0 91 GPM MOTORS PN Voltage Amps Watts HP Phase Hz ENC Haz Duty Wt Lbs Kg 30018 110V 8 5 825 1 1 50 6...

Page 9: ...r switch to the off position 0 and allow at least 10 minutes for the motor to cool Check the viscosity of lubricant being pumped to remain within limitations and resume operations Electric motors cannot be operated continuously and should not be operated for more than 30 minutes without cooldown CAUTION The Pneumatic Drum Pump motor 30019 has a recommended operating pressure of 90 psi 28 CFM Do no...

Page 10: ...reases Below is a general guideline for cleanliness levels ISO Oil Grade Classification Cleanliness Code R4 R6 R14 32 16 14 11 46 16 14 11 68 17 14 12 100 18 15 13 150 18 15 13 220 19 16 14 320 19 16 14 460 19 16 14 680 20 18 14 Determining the ISO Cleanliness level of equipment requires analysis of the running lubricating oil Trico s oil analysis laboratories can provide an accurate indication of...

Page 11: ...to an earthing electrode or to the building grounding system to prevent sparking between conductive equipment and grounded structures Grounding is an electrical connection between a metal vessel pump motor and a constant ground i e a metal rod driven into the earth Failure to bond and ground properly can cause a discharge of static electricity resulting in fire injury or death If in doubt do not s...

Page 12: ...ing from filter area Loose filter and or connections Check tightness of filter element to ensure proper seal check hose connections Fluid Leaking from Top of pump TFE Seal worn Remove motor adapter hand Wheel and bearing assembly and replace TFE seal Pneumatic motor turns slowly or does not function Air supply low Check air supply and ensure pressure is 90 psi Pneumatic motor improperly lubricated...

Page 13: ...1235 Hickory Street Pewaukee WI 53072 For Customer Support 800 558 7008 TRICO DRUM PUMP FILTRATION SYSTEM CONFIGURATION ...

Reviews: