8.
Attach the 2” MNPT Drum adapter onto the drum.
9.
Place some lubricant on the foot of the Drum Pump to help slide it past the O-ring when
inserting into the Drum adapter on the drum.
10.
Lift the unit and slide the pump foot into the drum adapter, guiding it until the foot
contacts the bottom of the drum.
11.
Using thread sealant, thread the hose onto the elbow connector and tighten (Figure 2)
12.
Place the filter gasket onto the groove on the filter head.
13.
Thread the filter onto the head and hand tighten.
14.
Use a strap wrench, place it at the top of the filter and tighten the filter ¼ turn to seat
the gasket
15.
Assemble the short grounding lead with clamp to the Drum pump side ensuring the
fastener is securely tightened.
16.
Use the additional supplied leads to bond the consecutive drums together; making sure
that one lead is connected to a grounded source. See NFPA 77.
Hose
Grounding Screw
Elbow Connector
Figure 2: Pump Assembly
Filter
Filter Head