1235 Hickory Street | Pewaukee, WI 53072
For Customer Support: 800-558-7008
DRUM PUMP SPECIFICATIONS
When filtering higher viscosity oils that exceed
1250 cSt
(
5500 SUS)
,
such as gear oils, the use of
a drum heating blanket is required to reduce the viscosity by heating the contents to 100°F
(40°C) or below 1250 cSt (5500 SUS). The minimum allowable micron level for higher viscosity
oil is 10 microns. Hydraulic oils may be filtered down to 3 microns at room temperature.
•
Viscosity range = 0 – 1,250 cSt (0-5,500 SUS)
•
Max Flow rate (181 cSt, ISO 68 @70F)= 7.25 GPM
•
Max Viscosity = 1,250 cSt (5,500 SUS)
•
Min Flow rate @ 1,250 cSt = 1.75 GPM
Average flow rates at room temp, 70°F (21.1°C), with 10 micron particle filter:
ISO 68 (188 cSt) ISO 100 (302 cSt)
ISO 220 (797 cSt)
ISO 320 (1250 cSt)
Electric Pump #30018
7.25 GPM
5.75 GPM
2.25 GPM
1.75 GPM
Pneumatic Pump #30019
6.0 GPM
5.25 GPM
1.75 GPM
0.91 GPM
MOTORS:
PN
Voltage Amps Watts HP
Phase
Hz
ENC
Haz. Duty Wt. Lbs(Kg)
30018 110V
8.5
825
1
1
50-60 TEFC (IP54)
NO
12.7 (5.7)
30021 220V
5
825
1
1
50-60 TEFC (IP54)
NO
12.7 (5.7
PN
HP Max Press. Min Hose Max dBA Airline Air Consumption Wt. Lbs(Kg)
30019 3/4
100 psi
3/8”
87
¼ NPT
28 CFM
3.4 (1.5)
0
1
2
3
4
5
6
7
8
9
10
0
100
200
300
400
500
600
700
800
900
1000 1100 1200 1300
Fl
ow
Ra
te (
GP
M
)
Viscosity (cSt)
Flow Rate Data with 10 Micron Filter and Electric Pump #30018