1235 Hickory Street | Pewaukee, WI 53072
For Customer Support: 800-558-7008
WARNING
•
The use of
30018 and/or 30021 Trico Drum Pump Electric
Motor
is prohibited with
flammable or combustible materials which could
cause serious injury or death if used.
•
When filtering higher viscosity oils, such as
ISO 460 and ISO 680
gear oils, the use of a drum
heating blanket is required to reduce the viscosity to under 1250 cSt (5500 SUS).
•
The minimum allowable micron level for higher viscosity oil is 10 microns. Hydraulic oils
may be filtered down to 3 microns at room temperature.
CAUTION
Bonding and ground safety procedures must be used when operating in hazardous duty
environments or when there is a danger of static discharge. See national Fire Protection Code
77 for proper grounding and bonding procedures. It is the responsibility of the operator to
properly inspect and ground equipment before use.
DRUM PUMP ASSEMBLY
1.
Place LV drum pump assembly on a worktable long enough to support the entire unit.
2.
Thread the Motor Drive Coupler onto the shaft and hand tighten.
3.
Place 3” Retaining Clip over the top of the LV drum pump assembly and slide over the
pump head to the top of tube filter connection.
4.
Place Hand Wheel on drum pump assembly with retaining ring groove facing down
toward pump foot.
5.
While holding the Hand Wheel onto the pump head, slide one end of the retaining ring
into the groove on the Hand Wheel.
6.
Use a flat headed screw driver to push the rest of the retaining ring into the groove.
7.
Test the Hand Wheel operation by turning it in either direction making sure it moves
freely.
Hand Wheel
Retaining Clip
Drum Pump
Figure 1: Hand Wheel
Motor Drive Coupler