background image

- 128 - 

Benefits of VLANs 

 

z

 

Grouping users into logical networks for performance enhancement.   

z

 

Provides effective broadcasts containment between Segmented Ports, which prevents 

flooding of a network. 

z

 

Offers security by completely isolating from each other the different Broadcast Domains 

connected on separate Segmented Ports.   

z

 

Preserving current investment in equipment and cabling.   

z

 

Providing an easy, flexible, economic way to modify logical groups when needed.   

z

 

Network administrators can easily "fine tune" the network.     

z

 

Keeping network structure from the physical topology of the cabling.   

z

 

Making large networks more manageable.   

 

You can group users according to some shared characteristic, such as a common business 

function or a common protocol. A single switch may have several independent VLANs within 

it. Below is a example that R&D, Manufacturing and Administration group can be partitioned 

into two different VLAN group, even members in different group can’t talk directly, but they 

still share the same server, such as MRP server, printer server in Adminstration group…etc. 

 

 

Summary of Contents for TEG-S2500i

Page 1: ...1 TEG S2500i 24 2G Stackable Switch User s Guide Version 11 01 4 26 2004...

Page 2: ...riately for safe shipment WARRANTIES EXCLUSIVE IF THE TRENDWARE PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE THE CUSTOMER S SOLE REMEDY SHALL BE AT TRENDWARE S OPTION REPAIR OR REPLACEMENT THE FOREGOIN...

Page 3: ...MAC TABLE 19 2 5 ADMINISTRATOR 20 2 5 1 IP and Management mode 20 2 5 2 Switch Setting 22 2 5 2 1 Advanced 22 2 5 2 2 Misc Config 23 2 5 3 Console Port Information 24 2 5 4 Port Controls 25 2 5 5 Trun...

Page 4: ...8 4 2 2 Trunk Configuration 70 4 2 3 VLAN Configuration 71 4 2 3 1 VLAN Configure 71 4 2 3 2 Create a VLAN Group 73 4 2 3 3 Edit Delete a VLAN Group 75 4 2 3 4 Groups Sorted Mode 76 4 2 4 Misc Configu...

Page 5: ...LACP Link Aggregation Control Protocol 111 4 3 5 1 Working Port Setting 111 4 3 5 2 State Activity 112 4 3 5 3 LACP Status 113 4 3 6 802 1x Protocol 115 4 3 6 1 Enable Disable 802 1x 115 4 3 6 2 802 1...

Page 6: ...setup of Single IP Agent mode network 131 5 4 SINGLE IP STACKING MODE APPLICATION USED WITH SWITCH USED WITH SWITCH 134 5 4 1 A guide to build up Stacking Switches 135 5 4 2 An Example of Port Base St...

Page 7: ...hrough the browser The User friendly drop down menu allows the user to easily learn control and monitor It supports not only traditional SNMP function but also RMON 1 2 3 9 groups for advanced network...

Page 8: ...Switch z Visually inspect the power cord and AC power connector z Make sure that there is proper heat dissipation form and adequate ventilation around the Switch Desktop or Shelf Installation When in...

Page 9: ...indicators should respond as fallows z All LED indicators will momentarily blink This blinking of the LED indicators represents a reset of the system z The power LED indicator will blink while the Sw...

Page 10: ...h 1 3 1 out of band Terminal mode Management First turn on your PC and execute with terminal mode program such as if you are in Microsoft Window environment you may choose super terminal from programs...

Page 11: ...your PC system Second in general within a network the members in the same network domain must have the same Subnet IP unless there are routers between them or members in the same network domain can t...

Page 12: ...n IP Address for your switch get IP Subnet Mask and get default gateway IP address if needed from your network manager Step 3 Modify the IP configuration value within the switch to match the rule In t...

Page 13: ...to the IP Configuration before executing the Telnet program Again after proper setting to the switch save the setting and connect your Ethernet cable from your PC to any port of the Ethernet Switch t...

Page 14: ...switch Each RJ 45 of 10 100M is with two LEDs built in on its upper corner left one indicates link status and activity while the right one indicates the speed information Each RJ 45 of 10 100 1000M fo...

Page 15: ...Address The unique hardware address assigned by manufacturer default Firmware Version Display the switch s firmware version ASIC Version Display the switch s ASIC version On the top of web page there...

Page 16: ...Display 1000Mbps or 100Mbps or 10Mbps speed port 1 24 are 10 100Mbps Port 25 26 are 10 100 1000Mbps 5 Duplex status Display full duplex or half duplex mode 6 Flow Control Full Display the flow control...

Page 17: ...k any port directly on the front panel of Home Page to get single port Status which is shown below There is a flow rate historical chart on the right User can track the flow rate of this port in the p...

Page 18: ...18 2 3 Port Statistics The following information provides a view of the current status of the whole unit Press Reset button to clean all count...

Page 19: ...ton will browse previous 50 or next 50 items The Top button will re list the table from the first MAC A sorting function is implemented here Clicking header on the top of table will bring a new sorted...

Page 20: ...ates which role this switch is currently playing Agent Slave means it is treated as a normal switch Agent Master means the Single IP is activated and the switch is treated as agent manager Stacking sl...

Page 21: ...ne as switch IP Different from original IP forwarding method it uses a method like webpage link and won t increase the loading of switch Agent IP setting and Agent management in the main menu will not...

Page 22: ...Max bridge transit delay bound control is enabled before enable Delay Bound because Enable Delay Bound must be work under Max bridge transit delay bound control is enabled situation Broadcast Storm Fi...

Page 23: ...g time in switch Default Max Delay Time is 255ms If the low priority packet stays in switch exceed Max Delay Time it will be sent The valid range is 1 255ms Qos Policy High Priority Levels 0 7 priorit...

Page 24: ...ion Console is a standard UART interface to communicate with Serial Port User can use windows HyperTerminal program to link the switch Connect To Configure Bits per seconds 9600 Data bits 8 Parity non...

Page 25: ...e of per port 5 Flows control Full User can set flow control function is enable or disable in full mode Half User can set backpressure is enable or disable in half mode 6 Rate Control port1 port 24 su...

Page 26: ...rt in security mode will be locked without permission of address learning Only the incoming packets with SMAC already existing in the address table can be forwarded normally User can disable the port...

Page 27: ...ports into a single dedicated connection This feature can expand bandwidth to a device on the network LACP operation requires full duplex mode more detail information refers to IEEE 802 3ad 2 5 5 1 A...

Page 28: ...as same as the group member ports 5 Select the ports to join the trunking group Allow max four ports can be aggregated at the same time 6 If LACP enable you can configure LACP Active Passive status i...

Page 29: ...tocol packets from the opposite device 1 A link that has either two active LACP ports or one active port can perform dynamic LACP trunking A link has two N A LACP ports will not perform dynamic LACP t...

Page 30: ...bers switches router or other network devices of group support IGMP With IGMP enable the member ports will detect IGMP queries report packets and manage the IP multicast traffic through the switch IGM...

Page 31: ...tic MAC Address 2 In the MAC address box enter the MAC address to and from which the port should permanently forward traffic regardless of the device s network activity 3 In the Port Number box enter...

Page 32: ...based on the destination addresses 1 In the MAC Address box enter the MAC address that wants to filter 2 If tag based 802 1Q VLAN are set up on the switch in the VLAN ID box type the VID to associate...

Page 33: ...up of network devices to another Layer 2 switch However all the network devices are still plug into the same switch physically The 24 2G switch supports port based 802 1Q tagged based and protocol bas...

Page 34: ...to send packets to different VLANs it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the pack...

Page 35: ...elect the members for the new VLAN 3 Click Apply 4 If there are many groups that over the limit of one page you can click the Next Page to view other VLAN groups NOTE If the trunk groups exist you can...

Page 36: ...o default VLAN VID is 1 The default VLAN can t be deleted GVRP GARP Generic Attribute Registration Protocol VLAN Registration Protocol GVRP allows automatic VLAN configuration between the switch and n...

Page 37: ...Protocol based VLAN classification User can combine the field Protocol Vlan and the field of the port number to form a new VLAN group NOTE IEEE 802 1v provides user to classify the packet through unta...

Page 38: ...u can see it in here ex TRK1 TRK2 and you can configure it is the member of the VLAN or not 6 Click Next Then you can view the page as follow 7 Uses this page to set the outgoing frames are VLAN Tagge...

Page 39: ...ing 24 2G switch each port allows user to set one PVID the range is 1 255 default PVID is 1 The PVID must as same as the VLAN ID that the port belong to VLAN group or the untagged traffic will be drop...

Page 40: ...o nodes on the network You can enable Spanning Tree Protocol on web management s switch setting advanced item select enable Spanning Tree protocol We are recommended that you enable STP on all switche...

Page 41: ...Tree Protocol configuration messages Enter a number 1 through 10 Forward Delay time You can change forward delay time The number of seconds a port waits before changing from its Spanning Tree Protocol...

Page 42: ...set mirror mode Disable Rx Tx Both 2 Analysis Port It means this port can be used to see all monitors port traffic You can connect analysis port to LAN analyzer or netxray 3 Monitored Port The ports...

Page 43: ...s data and then click Apply to update the changes on this page Name Enter a name to be used for the switch Location Enter the location of the switch Contact Enter the name of a person or organization...

Page 44: ...44...

Page 45: ...urity Manager On this page user can change user name and password with following steps 1 User name Type the new user name 2 Password Type the new password 3 Reconfirm password Retype the new password...

Page 46: ...Switch setting Advanced then you still to fill in the authentication server information Radius Server IP Address the IP address of the authentication server Server Port The UDP port number used by the...

Page 47: ...mine when an EAPOL PDU is to be transmitted Default value is 30 seconds Supplicant Timeout Used to determine timeout conditions in the exchanges between the supplicant and authentication server Defaul...

Page 48: ...g packet to send Press Apply to continue next page This page will display the result of the pinging IP It continues updating the Reply Counts when the ping packets are sending User can interrupt the p...

Page 49: ...IP switch with Single IP There are maximum 32 sets of information of network devices stored in the single IP switch and 16 sets in Stacking switch Basically these network devices should provide http...

Page 50: ...has the special need for this protocol port like virtual server The default port number is 28019 There are two ways to add the members Auto discover and Manual Auto discover method Press Find and the...

Page 51: ...ort base VLAN Note For the cause of http authentication mechanism it happens that web browser keeps asking administrator to input login name and password when agent manager changes a new host Typicall...

Page 52: ...ch loading a restriction confines here that only one remote user can access the agent manager in the same time Other user will be rejected if someone has launched the agent manger first The switch wil...

Page 53: ...ng to its configuration webpage Link Status The first page shows the current link status of all stacking members Link up ports will glow in their port numbers An off line switch will dim to gray if it...

Page 54: ...of stacking And all of their Giga ports are set to tag members to form a VLAN connection channel A strong warning declares here that the Stacking Tag VLAN is highly restricted to be modified or remove...

Page 55: ...ch The stacking switches interchange VLAN information through the Giga ports which are set to tagged members by Stacking Tag VLAN so a new VLAN should keep its Giga ports as tagged ones Since the mast...

Page 56: ...ress Delete to remove it There are two special cases for deleting VLAN The DEFAULT VLAN and Stacking Tag VLAN are undeletable A error message will pop up to cancel the task Stack VLAN also can t be ed...

Page 57: ...eated in the previous VLAN page 1 Select the PVID to be modified and choose the ports for this PVID value 2 Click Apply button to submit and a message Please wait to notice user to wait patiently 3 Wh...

Page 58: ...e and remote boot switch system Install TFTP program such as Turbo98 or Cisco TFTP and then execute Copy updated firmware image bin into TFTP server s directory In web management select administrator...

Page 59: ...n restore EEPROM value from here but you must put back image in ftp server switch will download back flash image 2 7 2 TFTP Backup Configuration Use this page to set tftp server ip address You can sav...

Page 60: ...60 2 8 Reset System Reset Switch to default configuration default value as below 2 9 Reboot Reboot the Switch in software reset...

Page 61: ...event will overwrite the oldest one All records will be kept in flash memory even after writing default unless user clears the event log Press Prev or Next button will browse previous 25 or next 25 s...

Page 62: ...re There are 2 cases to use 1k X modem to update firmware a User enters 1K X modem receiver mode through pressing any key within 5 seconds after system power on b System automatically enters 1K X mode...

Page 63: ...63 2 Press connected you will see CCCC displayed on console Then select Transfer Send File 3 Select 1K Xmodem in the Protocol item and give the place that image file folder Press Send button...

Page 64: ...64 4 Start download image file 5 Finish download image the switch system will update firmware automatic Update firmware ok the switch will reboot Please change the boudrate to 9600bps...

Page 65: ...serial interface to manage and monitor the switch user can follow the Console Port Information provide by web to use windows HyperTerminal program to link the switch 2 You can type user name and pass...

Page 66: ...ow the status of the switch Reboot Switch Restart the system or reset switch to default configuration TFTP Update Firmware Use TFTP to download image Logout Exit the menu line program Control Key The...

Page 67: ...ction menu line as follow provided in later configure page Actions Quit Exit the page of port configuration and return to previous menu Edit Configure all items Finished configure press Ctrl A Back to...

Page 68: ...tput rate control per unit is 100K The valid range is 0 1000 0 disable rate control 1 1000 valid rate value 3 Enabled User can disable or enable this port control Yes that mean the port is enable No t...

Page 69: ...ble or disable Half User can set half flow control function backpressure as enable or disable NOTE 1 Pressing Save only can save one page configuration 2 If the static trunk groups exist you can see i...

Page 70: ...of TRK1 TRK7 item Static the normal trunk LACP this trunk group have link aggregation control protocol 3 Press Ctrl A to go back action menu line 4 Select Save to save all configure value 5 If the ite...

Page 71: ...71 4 2 3 VLAN Configuration 4 2 3 1 VLAN Configure This page can set VLAN mode to port based VLAN or 802 1Q VLAN or disable VLAN function...

Page 72: ...rt VID 1 255 Type the PVID 2 NonMember Drop It matches that Ingress Filtering Rule 1 on web Forwarding only packets with VID matching this port s configured VID Press Space key to choose forward or dr...

Page 73: ...group ID The group ID rang is 1 4094 4 Member Press Space key to choose VLAN member There are two types to selected a Member the port is member port b No the port is NOT member port 5 Press Ctrl A go...

Page 74: ...ey to choose VLAN member There are three types to selected a UnTagged This port is the member port of this VLAN group and outgoing frames are NO VLAN Tagged frames b Tagged This port is the member por...

Page 75: ...e and then press enter 3 User can modify the protocol VLAN item and the member ports are tagged or un tagged and remove some member ports from this VLAN group 4 After edit VLAN press Save key to save...

Page 76: ...select VLAN groups sorted mode 1 sorted by name 2 Sorted by VID The Edit Delete a VLAN group page will display the result In the Edit Delete a VLAN Group page the result of sorted by name In the Edit...

Page 77: ...77 4 2 4 Misc Configuration...

Page 78: ...en back to action menu and press Save Reply Counts will display the result of pinging 4 2 4 2 MAC Age Interval Type the number of seconds that an inactive MAC address remains in the switch s address t...

Page 79: ...Filtering This page is configuring broadcast storm control 1 Press Edit to configure the broadcast storm filter mode 2 Press Space key to choose the threshold value The valid threshold value is 5 10 1...

Page 80: ...Queue Max Delay Time To set the time that low priority packets queuing in switch The valid range is 1 255ms Default Max Delay Time is 255ms NOTE Make sure Max bridge transit delay bound control is en...

Page 81: ...to save all configure value 5 You can press Next Page to configure port9 port26 press Previous Page return to last page 4 2 4 5 Collisions Retry Forever Collisions Retry Forever Disable In half duple...

Page 82: ...82 4 2 4 6 Hash Algorithm Select CRC Hash default or DirectMap for Hash algorithm 4 2 4 7 IFG Compensation Enable or disable the inter frame gap IFG compensation function...

Page 83: ...83...

Page 84: ...84 4 2 5 Administration Configuration 4 2 5 1 Change Username Use this page user can change web management user name Type the new user name and then press Save item...

Page 85: ...85 4 2 5 2 Change Password Use this page user can change web management login password 4 2 5 3 Device Information This page is provided to the user to configure the device information...

Page 86: ...86 4 2 5 4 IP Configuration User can configure the IP setting and fill in the new value...

Page 87: ...niffer port can be used to see all monitors port traffic Press Space key to choose it 4 Monitored Port The ports you want to monitor All monitor port traffic will be copied to sniffer port You can sel...

Page 88: ...88 4 2 7 Priority Configuration 4 2 7 1 Port Static Priority This static priority based on port if you set the port is high priority income frame from this port always high priority frame...

Page 89: ...eue Actions 1 Select Edit 2 Press Space key to select the priority level mapping to high or low queue 3 High Low Queue Service Ration H L User can select the ratio of high priority packets and low pri...

Page 90: ...in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powe...

Page 91: ...3 Port num press Space key to select the port number 4 Vlan ID If tag based 802 1Q VLAN are set up on the switch static addresses are associated with individual VLANs Type the VID to associate with t...

Page 92: ...to go back action menu line and then select Save to save all configure value Delete static MAC address Actions 1 Press Delete key 2 Choose the MAC address that you want to delete and then press enter...

Page 93: ...93...

Page 94: ...ser can add modify delete filter MAC address Add filter MAC address Actions 1 Press Add Edit key to add a filter MAC address 2 MAC Address Type the MAC address to filter 3 Vlan ID If tag based 802 1Q...

Page 95: ...Actions 1 Press Edit key 2 Choose the MAC address that you want to modify and then press enter 3 Press Edit key to modify all the items 4 Press Ctrl A to go back action menu line and then select Save...

Page 96: ...96...

Page 97: ...filter MAC address Actions 1 Press Delete key to delete a filter MAC address 2 Choose the MAC address that you want to delete and then press enter 3 When pressing Enter once will complete deletion on...

Page 98: ...guration 4 3 1 STP The Spanning Tree Protocol STP is a standardized method IEEE 802 1D for avoiding loops in switched networks When STP enabled to ensure that only one path at a time is active between...

Page 99: ...99 4 3 1 1 Enable Disable STP This page is showing the users how to enable or disable Spanning Tree function Press Space key to select enable or disable 4 3 1 2 STP System Configuration...

Page 100: ...tions 1 You can view spanning tree information about the Root Bridge on the left 2 On the right user can set new value for STP parameter NOTE All about the parameter description please see the section...

Page 101: ...s to determine which port are the forwarding ports 4 Priority This means priority port you can make it more or less likely to become the root port 5 Press Ctrl A back to action menu line 6 Select Save...

Page 102: ...ng the simple Network Management Protocol SNMP can be management the switch Use this page to define management stations as trap managers and to enter SNMP community strings User can also define a name...

Page 103: ...be used for the switch 3 System Contact Type the name of contact person or organization 4 System Location Type the location of the switch 5 System Description Type the description about the switch 6 P...

Page 104: ...name of current strings 2 Write Access Enable the rights is read only or read write Restricted Read only enables requests accompanied by this string to display MIB object information Unrestricted Read...

Page 105: ...ite Access Press Space key to select the right is restricted or unrestricted z Edit Community Name 1 Press Edit key choose the item that you want to modify and then press Enter 2 Community Name Type t...

Page 106: ...106 z Delete Community Name 1 Press Delete key 2 Choose the community name that you want to delete and then press enter 3 When pressing Enter once will complete deletion on delete mode...

Page 107: ...trap manager is defined no traps are issued Create a trap manager by entering the IP address of the station and a community string z Add SNMP trap manager 1 Press Add Edit to add the trap manager 2 I...

Page 108: ...new IP address 3 Community Name Type the community name 4 Press Ctrl A go to actions line press Save key to save all configure z Delete trap manager 1 Press Delete key 2 Choose the trap manager that...

Page 109: ...iguration information to be processed by the switch If a device sends a GVRP request using the VID of a VLAN defined on the switch the switch will automatically add that device to the existing VLAN Th...

Page 110: ...ernet Protocol IP suite This page you can enable disable the IGMP support Actions 1 Select Edit 2 IGMP Protocol Press Space key to choose Enable Disable 3 IGMP Query Mode Press Space key to choose Aut...

Page 111: ...and view all the LACP status Note All ports support LACP dynamic trunk group If connecting to the device that also supports LACP the LACP dynamic trunk group will be created automatically 4 3 5 1 Work...

Page 112: ...set this page you have to set trunk group on the page of Trunk Configuration first 4 3 5 2 State Activity Actions 1 Select Edit 2 Press Space key to choose the item Active The port automatically send...

Page 113: ...113 4 3 5 3 LACP Status When you re setting trunk group you can see the relational information here Static trunk group LACP trunk group...

Page 114: ...114 Actions Quit Exit this page and return to previous menu Previous Page Return to previous page to view Next page Go to the next page to view...

Page 115: ...115 4 3 6 802 1x Protocol This page can configure and view all the 802 1x status 4 3 6 1 Enable Disable 802 1x...

Page 116: ...116 1 Select Edit 2 Press Space key to choose Enabled Disabled 3 Press Ctrl A go back action menu line 4 Select Save to save configure value...

Page 117: ...his switch and authentication server 4 NAS Identifier A string used to identify this switch 5 Server Port The UDP port number used by the authentication server to authenticate 6 Accounting Port The UD...

Page 118: ...to choose Fu Fa Au No authorization status 3 Press Ctrl A go back action menu line 4 Select Save to save all configure value Note Fu Force the specific port to be unauthorized Fa Force the specific p...

Page 119: ...hentication server Default value is 30 seconds 5 Server Timeout Used to determine timeout conditions in the exchanges between the authenticator and authentication server Default value is 30 seconds 6...

Page 120: ...atus and Counters You can press the key of Tab or Backspace to choose item and press Enter key to select item 4 4 1 Port Status This page display every port status Link Status Display the port is link...

Page 121: ...eed and duplex FlowCtrl In auto Nway force mode display the flow control status is enable or not after negotiation In force mode display the flow control status is enabling or disable depending on use...

Page 122: ...ion Display the switch s Hardware version Module 1 Type Display the module 1 Type 1000Tx or 100Fx ext Depend on module card mode Module 1 information Display the information saved in EEPROM of module1...

Page 123: ...123 4 5 Reboot Switch 4 5 1 Default Reset switch to default configuration default value please section 2 4 14 4 5 2 Restart Reboot the switch in software reset...

Page 124: ...4 4 6 TFTP Update Firmware This page provide user to update firmware or restore EEPROM value or upload current EEPROM value 4 6 1 TFTP Update Firmware This page provides user use TFTP to update firmwa...

Page 125: ...When save successfully the image file download finished too 8 Restart switch 4 6 2 Restore Configure File This page user can restore EEPROM value save image file before form TFTP server Actions 1 Sta...

Page 126: ...estore the EEPROM value Actions 1 Start the TFTP server 2 Press Edit on this page 3 TFTP Server Type the IP of TFTP server 4 Remote File Name Type the image file name 5 Press Ctrl A go to action line...

Page 127: ...As a result each group of stations connected to separate Segmented Ports forms different isolated Broadcast Domain The Broadcast Sharing Ports should be used to connect servers and other common servi...

Page 128: ...ical groups when needed z Network administrators can easily fine tune the network z Keeping network structure from the physical topology of the cabling z Making large networks more manageable You can...

Page 129: ...r higher bandwidth service required You can use trunking to improve the throughput between segments Moreover this switch furtherly provides trunk with fail over function that is when one of the links...

Page 130: ...its own real IP inside the enterprise s network Privates IPs and NAT function provided by router gateway or IP sharing provide a solution to the shortage of real IP but new issue gives rise to that r...

Page 131: ...tacking mode up link in agent mode can be achieved through any port rather than Gigabit port only This provides great flexibility as long as network administrator can access them and hence Gigabit por...

Page 132: ...92 168 223 102 Gateway 192 168 223 254 LAN IP 192 168 223 254 WAN IP 211 23 53 250 Switch IP 192 168 1 100 Agent IP 192 168 223 100 Gateway optional IP 192 168 1 30 Switch IP 192 168 223 100 Agent IP...

Page 133: ...ces from example 2 are that master switch links directly to Internet and administrator from worldwide can access it through Internet Set the Switch IP and gateway of master switch to real IP 211 23 53...

Page 134: ...should be public for remote access through the Internet This will easily let the network administrator know the group settings e g tag based VLAN groups and link status among all stacked units A typic...

Page 135: ...of Single IP Stacking mode user can connect these stacking switches with Giga port in serial sequence Technically in Stacking Mode the Master Switch is able to connect control up to 31 Salve Switches...

Page 136: ...2 of Master 192 168 223 100 PC 1 192 168 223 92 on port 9 of Slave 4 192 168 223 140 PC 2 192 168 223 93 on port 23 of Slave 5 192 168 223 150 Port Base VLAN Group VLAN name test VLAN ID 10 Members Po...

Page 137: ...137 Result 1 PC 0 can access both PC 01 and PC 02...

Page 138: ...138 2 PC 0 can only access PC 02 only PC 01 will not reply...

Page 139: ...ith non stacking member The packet traffics between stacking members are transferred only through Giga module Trunking between stacking members may cause the spanning tree protocol STP to alter the to...

Page 140: ...arget 1 Any client with port 80 http go to company s default web server example 192 168 223 80 2 Any client with port 28010 go to agent stacking switch example 192 168 223 90 3 Any client can use the...

Page 141: ...211 23 53 252 28019 192 168 223 90 28019 Step 4 Modify Master s Agent IP to new IP other than its Switch IP Important According to the basic rule 2 of Single IP if administrator would like to access t...

Page 142: ...to Switch IP again before launching the Agent Stacking Manager TRENDware Technical Support 3135 Kashiwa Street Torrance CA 90505 Tel 1 310 891 1100 Fax 1 310 891 1111 E mail support trendware com www...

Reviews: