www.traxontechnologies.com
©2022 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
02/22 V1.3
7 of 23
2.2 Pre-Installation Checks
2.2.1
Installation Checklist
1. Prepare cables and all necessary accessories (Mounting Brackets, Waterproof Quick
Lock End Caps etc).
2. Perform functional check of Media Tubes
®
HO. Take care not to damage cables/
connectors during pre-installation checks.
3. Ensure all pre-installation checks laid out below have been followed.
4. Mount the Media Tubes
®
HO on-site. If the installation is to be left uncompleted
overnight, place all non-connected LED Engines and Media Tubes
®
HO in an indoor
environment.
Ensure all the Interconnection Cables, Media Tubes
®
HO and LED Engines are initially stored
in a dry area to guarantee the complete sealing of the system from water before installation.
2.2.2
Cable Bending
To reduce stress induced on Media Tube
®
HO lead cables, please adhere to the Minimum
Bending Radius of 10mm (0.4”) and the Non-Bendable Length of 20mm near the connector.
It is recommended to install lead cables through conduits/trunking.
FIG.5: Minimum Cable Bending and Non-Bendable Length requirement
Minimum Bending Radius
10mm/0.4”
Non-Bendable Length
20mm/0.79”
NOTE: Water ingress incurred due to cable twisting or excess cable bending will not be under
warranty by Traxon Technologies.