Maintenance of the StackMaster™ is required only when a StackMaster™
unit requires updating or fails. Recovery of a failed StackMaster™ unit
requires fault isolation, using methods provided in this section, and
corrective action. Corrective action is taken by simple procedures
described in this section or by contacting Transition Networks Technical
Support.
5.1
Fault Isolation
Use Table 5-1 for troubleshooting the StackMaster™ stack.
To use Table 5-1, locate the problem in the FAULT column. In the
PROBABLE CAUSE box next to the fault, find one or more probable
cause(s) associated with the fault. Examine each probable cause in turn,
beginning at the top. When the probable cause is identifed, take the
associated corrective action in the CORRECTIVE ACTION column.
FAULT
PROBABLE CAUSE
CORRECTIVE ACTION
Unit POWER LED
Disconnected
Connect power cord.
not illuminated
power cord.
Improperly
For 110-120V use,
installed fuse.
fuse should read 110-
120V in upright position;
for 210-240V use, fuse
should read 210-240V in
upright position.
Fuse failure.
Replace fuse. (See 5.3.1.)
Power supply
Contact TN Technical
failure.
Support.
1-800-260-1312
All LEDs
Faulty terminator
Install terminator (See
continuously
installation.
5.2.1)
illuminated
Inter-repeater cable
Install replacement inter-
failure.
repeater cable.
Terminator failure.
Contact TN Technical
Support.
1-800-260-1312
Table 5-1. Fault Isolation in the StackMaster™ Stack