3. INSTALLATION
3-17
MANAGEABLE HUB
3.7
Resetting StackMaster™ Stack
NOTE: The StackMaster™ Stack must be reset during installation to
initialize the internal software.
CAUTION: If the StackMaster™ Stack contains an SNMP Management
Unit or if an SNMP Management Board is installed in the 24-port
10BaseT Unit, the 6-port 10BaseFL Unit, or the 12-port 10BaseFL Unit
and the hub with the management board is installed at the top of the
Stack, DO NOT reset an individual hub. Reset the entire StackMaster™
Stack by resetting the SNMP Management Unit or the hub with SNMP
management board installed. In a managed StackMaster™ Stack,
resetting an individual Unit will cause the Unit to become invisible to the
SNMP Management software.
Managed Stack
•
If the StackMaster™ Stack is managed, use a jewelers screwdriver,
paper clip, or other small device to depress the reset switch inside the
SNMP Management Unit or the StackMaster™ Unit with SNMP
Management installed. The entire StackMaster™ Stack will recycle
and then resume normal operation.
Unmanaged Stack
•
Reset the StackMaster™ Units individually by using a jewelers
screwdriver, paper clip, or other small device to depress the reset
switch inside each StackMaster™ Unit. The StackMaster™ Unit will
recycle and then resume normal operation. Other hubs in the
StackMaster™ Stack will not be affected.