LIMITED WARRANTY

Seller warrants that the NEPTUNE Series Digital Indicator line will conform to written

specifications, drawings, and other descriptions made by the manufacturer, including any

modifications thereof. The Seller warrants the goods against faulty workmanship and defective

materials. If any goods fail to conform to these warranties, Seller will, as its sole and exclusive

liability hereunder, repair or replace such goods if they are returned within the following warranty

period:

Twelve (12) months from date of shipment from manufacturer.

These warranties are made upon the following TERMS and CONDITIONS:

This warranty is limited to the original equipment manufactured by TRANSCELL
TECHNOLOGY, INC. Items not covered under this warranty are batteries and normal wear
items like connectors, shrouds, front panels and fuses.
For the first sixty (60) days from the date of installation, the warranty covers parts, on-site
labor, and limited travel time and mileage. (3 hrs/150 miles maximum per occurrence).
After sixty (60) days, the warranty covers the cost of replacement parts only.
However, at the discretion and prior approval of TRANSCELL, certain equipment may be
returned , freight pre-paid, for repair, free of any parts or labor charges.  

TRANSCELL’s responsibility is confined to repair, replacement or credit of equipment of
parts. The warranty does not extend coverage to labor, material, freight or service charges
involved in removal, shipping or reinstallation of equipment or parts.

CONDITIONS WHICH VOID LIMITED WARRANTY:
This warranty shall not apply to equipment which:
A. Examination of such goods discloses that the nonconformity exists and was caused by

accident, misuse, neglect, alteration, improper installation improper or unauthorized repair,
improper testing, or an act of GOD including lightning and such goods have not been
modified, altered, or changed by any person other than the Seller or its duly authorized repair
agents.

Transcell Technology, Inc. will have a reasonable time to repair or replace such goods.

THESE WARRANTIES EXCLUDE ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL

OR WRITTEN, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY

OR FITNESS FOR A PARTICULAR PURPOSE. SELLER WILL NOT IN ANY EVENT BE LIABLE

FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

IN ACCEPTING THIS WARRANTY, THE PURCHASER OR BUYER AGREES TO WAIVE ANY

AND ALL OTHER CLAIMS FOR RIGHT TO WARRANTY FROM TRANSCELL TECHNOLOGY,

INC. SHOULD THE SELLER BE OTHER THAN TRANSCELL TECHNOLOGY, INC., THE

BUYER AGREES TO LOOK ONLY TO THE SELLER FOR WARRANTY CLAIM OR CLAIMS.

No terms, conditions, understanding, or agreements purporting to modify the terms of this

warranty shall have any legal effect unless made in writing and signed by a corporate officer of

the Seller.

Summary of Contents for NEPTUNE-5500 Series

Page 1: ...l Revision 2 7 June 29 2004 2003 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 1...

Page 2: ...ainst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Page 3: ...Taring an Item of Unknown Weight 12 3 3 3 Taring an Item of Known Weight 12 3 3 4 Clearing a Tare 12 3 3 5 Entering a min and max value 12 Chapter 4 Advanced Features and Operation 13 4 1 Item ID Stor...

Page 4: ...ard 7 2 2 Load cell connections 7 2 3 Pin assignments for load cell 7 3 1 NEPTUNE 5500 Keyboard Detail 9 3 2 Display detail 10 11 LIST OF TABLES 1 1 NEPTUNE 5500 Series Product Matrix 5 2 1 Keypad fun...

Page 5: ...readily send out check weight results to a PC or control other external devices The NEPTUNE 5500 is available in two platform sizes and four avoirdupois weight capacities If you are an installer the...

Page 6: ...ial printer to the COM1 serial port Connect the printer to the COM1 port using the optional serial cable See Appendix B for cabling requirements and pin outs Configure the communication parameters and...

Page 7: ...he Load Cell Terminal Color Wire Name RED Excitation BLK Excitation GRN Signal WHT Signal Figure 2 2 Color Codes for Shielded Load Cell Cable 1 If you do not wish to use the shielded load cell cable y...

Page 8: ...2 port designed for connection to either a PC or a serial printer COM2 is a 5 volt TTL port for connection to external relays Figure 2 1 shows the serial port connections to the main board 2 3 CONNECT...

Page 9: ...brightly or darkly lit areas 3 1 1 LIGHT EMITTING DIODE DISPLAY LED Figure below shows the display detail of the NEPTUNE 5500 Series As shown in Figure the scale displays weight information as well a...

Page 10: ...ow Gross Zero It is also used to move left in the user and configuration menus PRINT The PRINT key has two functions First it can be used to transmit an on demand output through the serial port to a p...

Page 11: ...e weight indication to stabilize If the item weight exceeds the scale s weight capacity it displays 000000 Read the weight shown on the display Note If you wish to change the unit of measure press the...

Page 12: ...he known minimum weight on the scale platform 4 Press the UNIT key until the MIN annunciators light and right digit blinks on the display 5 Press the SET GROSS key to enter minimum value 6 Scale momen...

Page 13: ...ic without additional hardware 4 1 1 SETPOINT OUTPUTS The Neptune 5500 has three annunciators on the front display to indicate UNDER ACCEPT or OVER If you want to use an external device to signal the...

Page 14: ...that there are no test weights on the platform press the ZERO key to zero out the displayed value 3 Press the SET key to save the zero point value The display will show SAVE then EndC0 momentarily th...

Page 15: ...followed by a value This value is the zero calibration value and should be recorded in the table below 3 Press down arrow again Scale will momentarily show CAL 1 followed by another value This value...

Page 16: ...entarily show ET C1 followed by the right digit flashing Use the directional keys to adjust the displayed value to the original calibration value 3 After setting the exact value press the SET key to s...

Page 17: ...e right arrow print or left arrow tare key to step through all the F parameters to get to the A menu 5 After completing changes in the setup menu slide the switch to its original position this will re...

Page 18: ...14 N A F13 N A F15 N A F17 Span Calib F16 Zero Calib F19 Key in Zero F18 Cal SpanView F21 Fac Dflt F20 Key in Span F22 N A F23 Scale Cap 1 2 5 1000 1500 2000 2500 500 3500 4000 5000 10000 3000 20000 3...

Page 19: ...must be in standstill to zero the scale 100 1 9 F5 Motion Band Sets the level at which motion is detected by comparing the present display update with the previous one If motion is not detected for tw...

Page 20: ...e left and right arrow keys to select the digit and the up and down arrow keys to adjust the digit Set key to save Press DOWN ARROW key to begin sequence F20 Key in Span Allows you to key in a known s...

Page 21: ...A7 Operator ID A8 Time Entry A9 Time Format A10 Date Entry A11 Date format A15 Print Item ID A14 N A A13 Set Com Port A12 N A A21 Print ID A20 Print T D A19 Print Net A18 Print Tare A17 Print Gross A...

Page 22: ...in print format Us the left right arrow keys to select digit and up down arrow keys to change value Press Set key to enter Press Down Arrow key to begin A8 Time Entry Actuates the function that allows...

Page 23: ...E value 0 Disable 1 Text Only 2 Text Bar code A19 Print Net Allows operator to print the NET weight value 0 Disable 1 Text Only 2 Text Bar code A20 Print Time Date Allows operator to print the TIME DA...

Page 24: ...Neptune 5500 10 VDC 4 x 350 load cells SERIAL COMMUNICATIONS Serial Port Full Duplex 1200 2400 4800 9600 Baud 8 data bits no parity 1 stop bit 7 data bits odd parity 1 stop bit 7 data bits even parity...

Page 25: ...rface to a PC Figure B 2 shows the serial data format for the Demand Mode INDICATOR PC 2 RXD RXD 2 TXD 3 S GND 5 3 TXD 5 S GND 6 DSR 4 DTR 8 CTS DSUB9 DSUB9 FIGURE B 1 Cable Diagram for Indicator to I...

Page 26: ...value C This command is sent to the indicator to toggle among the configured units B 1 2 PRINT TICKET MODE The Print Ticket Mode is designed specifically for a serial printer and is selected by setti...

Page 27: ...ating The transmission occurs at the end of each display update Figure B 5 shows the serial data format for Continuous Mode STX POL xxxxx xx L K G N STAT CR LF Polarity SP Positive Negative Weight Dat...

Page 28: ...confined to repair replacement or credit of equipment of parts The warranty does not extend coverage to labor material freight or service charges involved in removal shipping or reinstallation of equ...

Reviews: