MS-SVN056C-EN
45
Power Specifications
Convertible unit
Power specification (power supply to indoor unit)
Power specification (power supply to outdoor unit)
Power specification (independent power supply)
Model
18
24
36
48
60
Voltage
Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
Voltage
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
Circuit breaker/fuse
(A)
20/16
40/25
50/30
60/45
60/50
Model
18
24
36
48
60
36
48-60
Voltage
Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
3 Phase
3 Phase
Voltage
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
Circuit breaker/fuse
(A)
20/16
40/30
60/40
70/55
70/60
32/25
45/35
Model
18
24
36
48
60
36
48-60
Power
(indoor)
Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
Voltage
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
Circuit breaker/fuse
(A)
20/16
20/16
20/16
20/16
20/16
20/16
20/16
Power
(outdoor)
Phase
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
3 Phase
3 Phase
Voltage
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
208 - 240V
Circuit breaker/fuse
(A)
20/16
40/25
50/30
60/45
60/50
32/25
45/35
Summary of Contents for 2MCC05-C
Page 24: ...24 MS SVN056C EN Concealed Unit Installation Performance Curves...
Page 25: ...MS SVN056C EN 25 Concealed Unit Installation...
Page 71: ...MS SVN056C EN 71 Wiring Diagrams Outdoor Unit Cooling Only 4TTK05 D 36K 3 Phase...
Page 72: ...72 MS SVN056C EN Wiring Diagrams Outdoor Unit Cooling Only 4TTK05 D 48K 3 Phase...
Page 73: ...MS SVN056C EN 73 Wiring Diagrams Outdoor Unit Cooling Only 4TTK05 D 60K 3 Phase...
Page 74: ...74 MS SVN056C EN Wiring Diagrams Outdoor Unit Cooling Only Heat Pump 4TWK05 D 36K 3 Phase...
Page 75: ...MS SVN056C EN 75 Wiring Diagrams Outdoor Unit Cooling Only Heat Pump 4TWK05 D 48K 3 Phase...
Page 76: ...76 MS SVN056C EN Wiring Diagrams Outdoor Unit Cooling Only Heat Pump 4TWK05 D 60K 3 Phase...
Page 78: ......
Page 79: ......