Tradedor TD77DM & TD77SEL Installation Guide
fig.9.9
fig.9.10
fig.9.8
A
B
C
Please be aware! During set up the
motor may reach thermal cut out.
If this occurs you will need to wind
the door down manually to allow
air to pass over the barrel and
cool. This can take up to 45 mins.
If the door stops (due to thermal
cut out), or once completed the
error light is on or flashing, then
you will need to clear the memory
of the base rail unit and handsets
before restarting the whole procedure
(refer to page 28 to clear memory).
1
The curtain must be all the way down in the
closed position before starting.
2
Press and hold the “PROG” button on the receiver
box main board for 2 seconds until the red LED
lights up and stays on
(fig.9.10)
. This can be found
in the bottom right next to the dipswitches.
3
Press “START” button (next to “PROG” button)
(fig.9.10)
. The door will now start a setup process.
4
Wait for several seconds and the "PROG" light
will turn off. Door set up is now complete.
1
The door will open slightly and close again.
2
The door will then open and fully stop.
3
Press & release the "START" button again
(fig.9.10)
and the door will close.
4
On final closing, when the door is 20mm from
the floor, press and release "START" button.
The door will carry on moving but the red light
above "PROGRAM" will flash purple & red.
Programming Run Timers & Limits
(SAFETY EDGE)
26
Summary of Contents for TD77DM
Page 1: ...Tradedor TD77DM TD77SEL Installation Guide TD77DM TD77SEL Installation Guide...
Page 2: ...Tradedor TD77DM TD77SEL Installation Guide Finished door 1 Installation Guide...
Page 11: ...Tradedor TD77DM TD77SEL Installation Guide Finished door from inside 10...
Page 42: ...Tradedor TD77DM TD77SEL Installation Guide Notes...
Page 43: ...Tradedor TD77DM TD77SEL Installation Guide Notes...