TR SECURITY Mamba II Installation Manual Download Page 9

Installation manual 

 Mamba II

PREPARATION OF RG59 CABLE 

When preparing the cable RG59 follow Figure 10: 

unscrew the end of the joint;

put the rubber seal from the cable gland;

remove the isolation of the cable RG59 at distance 42 to 44 mm;

split shielding to separate wires;

wrap the shielding by tinned wire and keep 35-40 mm for
connection to a terminal;

remove the centre cable isolation and keep 15-20 mm;

fold the centre cable in half due to the amplification of diameter
of the cable. Keep about 12 mm because of terminal connection;

ensure that the length of both ends is at least 6 mm.

PREPARATION OF SENSTIVE CABLE 

Preparation of sensoric cable describe following Fig.11): 

unscrew the end of the joint;

put the rubber seal to the cable from the cable gland;

remove the isolation from 35 to 40 mm;

cut off the isolation foil about 9-11 mm from the left edge of
isolation;

cut off the shielding wire about 9-11 mm from the left edge of
isolation;

bend the cable shield (including foil) toward the existing 
isolation;

wrap the shielding with tinned wire for a distance of 35-40 mm;

remove the isolation of all central wires at around 30- 32 mm;

put all centre wires together;

ensure that the length of the central wires are at least 6 mm.

CABLE CONNECTION 

Fig.12: 

Cable joint for connection of sensitive and non-sensitive cable 

Fig. 11: 

Preparation of detection cable 

Fig. 10: 

Preparation of RG59 cable 

Summary of Contents for Mamba II

Page 1: ...Version 2013 2 Installation manual Mamba II...

Page 2: ...ons and tips for assembly 5 3 Installation 6 3 1 Instalation of the device 6 Important notice 6 3 2 Cabeling 8 Preparation of RG59 cable 9 Preparation of senstive cable 9 Cable connection 9 Cable term...

Page 3: ...immediately generates an alarm signal The sensor is typically mounted directly to the fence or fence posts see Chapter 1 4 Installation requirements and procedures Sensing cable is securely fastened t...

Page 4: ...su cient cable tension and uniform strength of tightening strips It is advantageous to use a special mounting strips tongs If the cable is routed through a column or other reinforcement set higher ten...

Page 5: ...metal fence Wooden fence Barber fence There is possibility to use standard mounting method in most cases for the wired fences If you would like to install system to the concrete or other solid fence...

Page 6: ...m diameter of 1 mm see Fig 5 Minus pol of power supply IS NOT grounding of the sensor Before connecting the sensor to the installed cable be sure that the impedance between the cable shield and wires...

Page 7: ...y 1 32 see Section 3 3 Controls Rotary switch 0 9 Sensitivity 0 lower 9 higher Terminals IN Connection of sensitive detection cable Terminal IN wires and GNDA shield GNDA NC1 Output ALARM normally clo...

Page 8: ...VIBRO cable Connection of the cable and the sensor Use the special joints for connecting cables and sensor MAMBA There are two types of cable connectors The first is for transform sensitive cable to...

Page 9: ...ATION OF SENSTIVE CABLE Preparation of sensoric cable describe following Fig 11 unscrew the end of the joint put the rubber seal to the cable from the cable gland remove the isolation from 35 to 40 mm...

Page 10: ...ity This sensitivity is used mainly for solid fences Switch no 2 see Chapter 3 4 Testing mode Switch no 3 switching ON OFF reed relay on mainboard which is connected in serial with output NC2 Connecti...

Page 11: ...een Not used in test mode When adjusting the sensitivity proceed as follows Switch ON Test mode Turn off extra sensitive mode DIP switch no 1 Set the rotary switch to the middle sensitivity Check the...

Page 12: ...a slight delay about 1 second tested the integrity of the sensor and cable If the cable is connected integrity of the cable is OK and is properly terminated after a while the yellow LED goes out If th...

Page 13: ...f the software Setting the address of the sensor is described in chapter 3 3 Controls Speed of communication BUS is in default set to 19 200 Baud do not change this setting Is necessary to set right a...

Page 14: ...this section you can set the sensor detection algorithm for the particular type of installation WIRED FENCE this setting is right for most types of the flexible fences SOLID FENCE Sensitive algorithm...

Page 15: ...ES AND CONDITIONS writing to memory start automatically after selecting value in the menu You can adjust reducing of sensitivity in the pop up menu digital input Activation is performed by connection...

Page 16: ...h on the mainboard of the sensor When you connect the sensor software automatically retrieves the current sensitivity setting from EPROM Writing new settings to memory start automatically after select...

Page 17: ...er voltage level is lower than value set in the pop up menu 5 Shaking activation of tilt detector 6 End terminal error of termination terminator on the cable is not connected or integrity of the cable...

Page 18: ...of small signal levels The horizontal dashed lines shows the alarm level If the signal exceeds a preset threshold detection algorithm evaluates alarm values red curve shows the alarm status This cond...

Page 19: ...the values from the sensor Software show signal waveforms on a graph and display current values on tab detail If you want to make forensic analysis of the recorded values stop reading 2 Save Load dat...

Page 20: ...lly inserted Check all cable joints Check all cable connections The yellow LED T1 illuminates Cover of the sensor is open tamper ALLWAYS Reed Relay on the main board has not on the other side magnet a...

Reviews: