TR SECURITY Mamba II Installation Manual Download Page 3

Installa

tio

n manual – Mamba II

1. GENERAL  INFO

1.1. DESIGN 

MAMBA perimeter system is primary designed t

o

 secure perimeter 

o

f the 

o

bjects, especially fences. It can be used

 for 

unde

rgro

und installa

tio

n, 

co

ncrete walls, the pr

otectio

o

f s

o

lid 

o

bjects such as

 solar

 panels etc. 

This alarm system generates an alarm when intruder trying t

o

 

o

verc

o

me a fence 

o

r any a

tt

empt 

o

f intrus

ion

. System 

als

o

 testing 

co

nstantly 

o

verall integrity 

o

f the cable (dis

co

nne

ctio

n, sh

o

rt-circuit). 

1.2. PRINCIPLE OF OPERATION 

The general principle is based 

o

n fact that the de

tectio

n cable 

generates small trib

o

electric signal. This signal (sta

tic 

electricity) is due t

o

 fri

ctio

n between the dielectric and the 

co

pper 

core o

f the cable. Def

o

rma

tio

o

f the cable and 

f

rictio

n in the cable will generate signal in the m

o

ment 

o

f the 

intrus

io

n. If the cable is well c

o

nnected t

o

 the fence all fence 

w

o

rking like sensi

ti

ve intrusi

o

n de

tector

Whenever the intruder will a

tte

mpt t

o

 handle any fence 

o

cable, the system immediately generates an alarm signal. 

The sens

o

r is typically

 mo

unted directly t

o

 the fence 

o

r fence p

o

sts (see. Chapter 

1.4 Installation requirements and 

procedures

). Sensing cable is securely fastened t

o

 the fence using a plas

tic o

r metal cable 

tie

s. The number

 o

f strips is 

an im

po

rtant parame

ter for

 the 

o

verall system behav

io

ur and sensi

ti

vity. Generally: smaller number

 o

f the strips is 

used t

o fix 

the cable it will decrease the sensi

ti

vity 

o

f the system and it may cause false alarms. 

System is pr

oo

fed a re

co

mmended t

o

 use with shielded cable ca

tegor

y 5 – it means cable “FTP Cat 5E“ 

o

r “STP Cat 

5E“. They can als

o

 be used in 

o

ther types 

o

f c

o

mmun

icatio

n cables that are suitable

 for

 its characteris

ti

cs par

tic

ularly 

resistance in an 

o

utd

oo

r envir

o

nment and als

o

 their c

o

nstru

ctio

n. The system als

o

 supp

o

rts a special kind 

o

f sensing 

cable called “vibr

o

cable” which is typically used

 for

 

fix

ed 

co

ncrete fences 

o

r unde

rgro

und installa

tio

ns. Vibr

o

cable and 

o

ther n

o

n-re

co

mmended cable 

co

nsult with y

o

ur supplier. 

The system c

on

sists 

o

f the f

o

ll

o

wing 

compo

nents (see. Fig. 1): 

sens

o

r MAMBA (1)

n

o

n sensi

ti

ve cable (2)

cable jun

ctio

n b

ox

 (3)

sens

iti

ve cable (4)

termina

tio

n (5)

Fig. 1: 

Diagram of the system

 

Summary of Contents for Mamba II

Page 1: ...Version 2013 2 Installation manual Mamba II...

Page 2: ...ons and tips for assembly 5 3 Installation 6 3 1 Instalation of the device 6 Important notice 6 3 2 Cabeling 8 Preparation of RG59 cable 9 Preparation of senstive cable 9 Cable connection 9 Cable term...

Page 3: ...immediately generates an alarm signal The sensor is typically mounted directly to the fence or fence posts see Chapter 1 4 Installation requirements and procedures Sensing cable is securely fastened t...

Page 4: ...su cient cable tension and uniform strength of tightening strips It is advantageous to use a special mounting strips tongs If the cable is routed through a column or other reinforcement set higher ten...

Page 5: ...metal fence Wooden fence Barber fence There is possibility to use standard mounting method in most cases for the wired fences If you would like to install system to the concrete or other solid fence...

Page 6: ...m diameter of 1 mm see Fig 5 Minus pol of power supply IS NOT grounding of the sensor Before connecting the sensor to the installed cable be sure that the impedance between the cable shield and wires...

Page 7: ...y 1 32 see Section 3 3 Controls Rotary switch 0 9 Sensitivity 0 lower 9 higher Terminals IN Connection of sensitive detection cable Terminal IN wires and GNDA shield GNDA NC1 Output ALARM normally clo...

Page 8: ...VIBRO cable Connection of the cable and the sensor Use the special joints for connecting cables and sensor MAMBA There are two types of cable connectors The first is for transform sensitive cable to...

Page 9: ...ATION OF SENSTIVE CABLE Preparation of sensoric cable describe following Fig 11 unscrew the end of the joint put the rubber seal to the cable from the cable gland remove the isolation from 35 to 40 mm...

Page 10: ...ity This sensitivity is used mainly for solid fences Switch no 2 see Chapter 3 4 Testing mode Switch no 3 switching ON OFF reed relay on mainboard which is connected in serial with output NC2 Connecti...

Page 11: ...een Not used in test mode When adjusting the sensitivity proceed as follows Switch ON Test mode Turn off extra sensitive mode DIP switch no 1 Set the rotary switch to the middle sensitivity Check the...

Page 12: ...a slight delay about 1 second tested the integrity of the sensor and cable If the cable is connected integrity of the cable is OK and is properly terminated after a while the yellow LED goes out If th...

Page 13: ...f the software Setting the address of the sensor is described in chapter 3 3 Controls Speed of communication BUS is in default set to 19 200 Baud do not change this setting Is necessary to set right a...

Page 14: ...this section you can set the sensor detection algorithm for the particular type of installation WIRED FENCE this setting is right for most types of the flexible fences SOLID FENCE Sensitive algorithm...

Page 15: ...ES AND CONDITIONS writing to memory start automatically after selecting value in the menu You can adjust reducing of sensitivity in the pop up menu digital input Activation is performed by connection...

Page 16: ...h on the mainboard of the sensor When you connect the sensor software automatically retrieves the current sensitivity setting from EPROM Writing new settings to memory start automatically after select...

Page 17: ...er voltage level is lower than value set in the pop up menu 5 Shaking activation of tilt detector 6 End terminal error of termination terminator on the cable is not connected or integrity of the cable...

Page 18: ...of small signal levels The horizontal dashed lines shows the alarm level If the signal exceeds a preset threshold detection algorithm evaluates alarm values red curve shows the alarm status This cond...

Page 19: ...the values from the sensor Software show signal waveforms on a graph and display current values on tab detail If you want to make forensic analysis of the recorded values stop reading 2 Save Load dat...

Page 20: ...lly inserted Check all cable joints Check all cable connections The yellow LED T1 illuminates Cover of the sensor is open tamper ALLWAYS Reed Relay on the main board has not on the other side magnet a...

Reviews: