Resistance to strong winds can be observed in the test mode in windy weather. The signal level indicator should
remain spontaneously in the wind at more than 3 pieces of signal. You can check in the windy weather also the
stability of the tension mesh fence and stability of all parts of the fence. Remove the mechanical deformation of
the cable.
3.5. FIRST START
Switch ON the sensor
When the power supply is connected
–
first is green LED light, then blink yellow and finally red LED.
Now is a slight delay (about 1 second) tested the integrity of the sensor and cable.
If the cable is connected, integrity of the cable is OK and is properly terminated, after a while, the yellow LED goes
out.
If the sensor is working properly, the red LED will also be illuminated for approximately one second.
Now is system ready for use.
The described behaviour is valid if the sensor in the factory setting. The control software can change the
configuration of fault LEDs. Setting fault diodes is derived from the software settings.
The described behaviour is valid if the sensor in the default factory setting. The control software can change the
configuration of trouble LEDs. Software settings can change status of trouble diodes.