5.
Saved configuration:
Used to store the current configuration of the connected sensor and re-load from a saved file.
6.
Test-mode:
This tab is used to diagnose detector as a telnet client for deeper diagnostics and communication with the
detector. On the right side are two buttons that are used to initialize the detector (reboot) and a button to
retrieve the status of the detector.
7.
Signal amplifier
:
Rotary button adjusts the sensitivity of the detector by analogy with hardware rotary switch on the
mainboard of the sensor. When you connect the sensor
–
software automatically retrieves the current
sensitivity setting from EPROM. Writing new settings to memory start automatically after selecting value by
rotary button.
Button
Extra
activate sensitivity in higher range. This sensitivity is mostly used for special installations where
is necessary to use high sensitivity of the sensor algorithm.
.
WARNING!!!
All the values that you set using the control software, rewriting manually adjusted values of the rotary switch
on mainboard of the sensor. Each additional manual change by rotary switch in opposite rewrites the
software set parameters. The software always reads the last set values from memory either HW or SW.