Installation manual
–
Mamba II
CABLE TERMINATION
Please observe the following instructions for terminating cable
For the termination of the cable, use the provided cable joint. For termination (balancing) use the supplied cable
termination element (resistor) and connect it between the shield and the centre wires (signal and ground).
Fig.13:
Cable joint for termination of the cable
3.3. CONTROLS
DIP SWITCH
1
Extra sensitivity
2
Activation of test mode (see. Chapter 3.4. Testing mode)
3
Switch ON / OFF reed relay on mainboard
4-8 Address for RS485 BUS
Switch no. 1
is used for main level of sensitivity. If switch is ON
–
sensor working in HIGH level of sensitivity. This
sensitivity is used mainly for solid fences.
Switch no. 2
see Chapter 3.4. Testing mode
Switch no. 3
switching ON / OFF reed relay on mainboard, which is connected in serial with output NC2. Connection of
the reed relay is fixed by hardware connection and it is not possible to change it by control software. If you do not
need to use reed relay - toggle Switch no.3 to ON position.
Switch no. 4-8
are used for settings of BUS address. This is described in the following table:
DIP
1 2 3 4 5 6 7 8
DIP
1 2 3 4 5 6 7 8
address 1
●
address 17
●
●
address 2
●
address 18
●
●
address 3
●
●
address 19
●
●
●
address 4
●
address 20
●
●
address 5
●
●
address 21
●
●
●
address 6
●
●
address 22
●
●
●
address 7
●
●
●
address 23
●
●
●
●
address 8
●
address 24
●
●
address 9
●
●
address 25
●
●
●
address 10
●
●
address 26
●
●
●
address 11
●
●
●
address 27
●
●
●
●
address 12
●
●
address 28
●
●
●
address 13
●
●
●
address 29
●
●
●
●
address 14
●
●
●
address 30
●
●
●
●
address 15
●
●
●
●
address 31
●
●
●
●
●
address 16
●