Installation manual
–
Mamba II
2.
History TAB:
Here you have an overview of the overall history of the waveform graph and you can use the scroll bar to move faster
in time. For moving in the time is also used the hand icon located above the chart - see. SECTION C.
3.
Detail TAB
This tab provides deeper technical information about the state of the sensor and values. Used to diagnose connection
and analyse the status of the unit. For further information please contact your supplier.
SECTION C
1.
Graph of signal values from the detector.
The
yellow
curve represents the signal in the range from 0.1 to 4 Hz. The
blue
curve is the result of mathematical
analysis for the value of small signal levels. The horizontal dashed lines shows the alarm level. If the signal exceeds a
preset threshold, detection algorithm evaluates alarm values
- red
curve shows the alarm status. This condition is
followed by activation of the alarm relay - the sensor is in alarm.
2.
Enabling of individual curves
Press the appropriate button to activate / deactivate the line on the graph.
3.
Control of the chart
In the pop-up menu Trigger 1,2 you can set alarm levels for actual graph. If you can change trigger level of the sensor
use symbol
in the graph. This level automatically change detection algorithm and has a significant impact on the
final sensor sensitivity.
Hand symbol is used to scroll the chart. To facilitate the work, stop reading the chart, otherwise the chart will
automatically move to the end.
The symbol of the grid can activate / deactivate the grid.
1
3
2