Notes
Notes
11
Plywood, etc.
Reinforcing
wooden block
Cover
Flange
Finished wall
surface
Nut
Mounting plate
Through hole
(
φ
8)
Continuous-thread
stud
45 to 60
9 to 16
Washer
①
Mount reinforcing wooden blocks of 45 to 60
mm in thickness on the handrail mounting
area beforehand.
②
Carry out centering and then make
φ
8-mm
through holes for continuous-thread studs.
③
Screw the continuous-thread studs into the
bolt holes of the mounting plate and tighten
them with nuts.
④
Insert the continuous-thread studs into the
through holes, put the mounting plate on the
back of the wall, and tighten with washers
and nuts from the handrail mounting side.
⑤
After finishing the wall, adjust the projecting
length of the continuous-thread studs to be
between 9 and 16 mm from the finished wall
surface.
⑥
Put the continuous-thread studs through the
mounting holes of the flange, and then
tighten with the washers and nuts.
⑦
Press the cover against the finished surface.
①
Carry out centering and then make
through holes of
φ
8 mm for
continuous-thread studs.
②
Screw the continuous-thread studs into
the bolt holes of the mounting plate and
tighten them with nuts.
③
Insert the continuous-thread studs into
the through holes, put the mounting
plate on the back of the wall, and
tighten with the washers and nuts from
the handrail mounting side.
④
After finishing the wall, adjust the
projecting length of the
continuous-thread studs to be between
9 and 16 mm from the finished wall
surface.
⑤
Put the continuous-thread studs
through the mounting holes of the
flange, and then tighten with the
washers and nuts.
⑥
Press the cover against the finished
surface.
Note 3
(Unit: mm)
Finished wall
surface
9 to 16
125 or less
Concrete block
Mortar
Mounting plate
Cover
Flange
Through hole (
φ
8)
Washer
Nut
Continuous-thread
stud
Note 3
(Unit: mm)
7
-4
. Installing the Handrail
Wooden base: Fixing by clamping a mounting plate
Concrete block base: Fixing by clamping a mounting plate
Fixing bracket part number T110D11,T110D62,T110D43
Fixing bracket part number
T110D11,T110D62,T110D43
Note 1
Notes 2 and 4
Note 1: Mount reinforcing wooden blocks of 45 to 60 mm in thickness securely
on a strong pillar, etc.
Note 2: Adjust the projecting length of the continuous-thread studs to be
between 9 and 16 mm from the finished wall surface.
Note 3: Be careful not to overtighten the nuts to avoid tiles from breaking.
Note 4: If the bolts are not long enough, procure M6 continuous-thread studs
in the field.
Note 1: It is not necessary to fill hollows with mortar, etc.
Note 2: Adjust the projecting length of the continuous-thread studs to be
between 9 and 16 mm from the finished wall surface.
Note 3: Be careful not to overtighten the nuts to avoid tiles from breaking.
Note 4: If the bolts are not long enough, procure M6 continuous-thread studs
in the field.
Note 1
Notes 2 and 4