– 16 –
INTERFACE MANUAL
STE 85457
Section 2
Power Cable
2.1
Connecting the Power Cable
To connect the TSL3000E/TSL3100E power cable, use the attached connector.
Robot controller side
User side
AC IN
R
L1
S
L2
A
B
D
FG
PE
Single-phase
190-240 VAC
50/60 Hz
C
Fig. 2.1 Connection of power cable
Plug connector model: JL04V-6A18-10SE-EB
Manufacturer: JAE (Japan Aviation Electronics Industry,
Limited)
JL04-18CK(13)
Manufacturer: JAE (Japan Aviation Electronics Industry,
Limited)
Cable:
2.0 mm
2
(AWG#14)
The cable is not included in the accessories. The attached plug connector
connected to the ACIN of the controller is soldering type. The customer must use
the attached connector to fabricate the cable.
Table 2.1 Power Supply Specifications
Power supply
Single-phase 190-240 V AC
50/60 Hz
1 Hz
Power capacity
Varies depending on the robot to
be connected.
Instantaneous power failure
40 msec or less
Ground
Class D dedicated grounding
Be sure to ground the PE ground terminal to prevent electric shock.