– 124 –
INTERFACE MANUAL
STE 85457
Name
I/O
Function
Signal judgment
EMG-IN*
~ EMG-OUT*
I
Emergency-stops the robot.
ON:
Open
OFF: Short-circuit
SAD-IN*
~ SAD-OUT*
I
Emergency-stops the robot.
ON:
Open
OFF: Short-circuit
ACK
O Serves as a response signal to input
signals STROBE, PRG_RST,
STEP_RST, CYC_RST and DO_RST.
ON:
High
OFF: Low
SV_RDY
O This signal is output when the servo
power is turned on and the robot is
ready to start.
ON:
High
OFF: Low
EXTSIG
O This signal is output when the EXT.
SIGNAL mode is selected by means of
the MODE switch.
ON:
High
OFF: Low
SYS_RDY
O System ready signal
ON:
High
OFF: Low
AUTORUN
O This signal is output while the program
is executed in automatic operation.
ON:
High
OFF: Low
CYC_END
O This is the output signal for verifying that
the program has stopped by the CYCLE
signal input.
ON:
High
OFF: Low
LOW_ST
O This signal is output while the robot is
operating at a low speed by the input of
low speed command.
ON:
High
OFF: Low
BT_ALM
O Battery voltage level error output for
backup power supply.
ON:
High
OFF: Low
ALARM
O Controller fault output.
ON:
High
OFF: Low
SVON-1a
~ SVON-COM
O Servo power ON contact output.
ON:
Contact open
OFF: Contact close
Non-voltage contact
Summary of Contents for TSL3000E