– 108 –
INTERFACE MANUAL
STE 85457
8.1.2
Connecting the Extension Output Signal Cable
The connection of the extension output signal cable uses the connector XM3A-2521
(plug type) and XM2S-2511 (connector cover) supplied with the TR48DIOCN. The
TR48DIOCN outputs (DO_101 to DO_120 (Station 0) and DO_133 to DO_152
(Station 1), are connected to the connector OUTPUT on the module panel.
OUTPUT
TR48DIOCN
User side
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
CASE
P24V
P24V
P24V
P24V
P24V
Station 0/Station 1
to
P24G
Sink type
(
- common)
DO_101
DO_120
to
DO_133
DO_152
Note 1: The DO_101 to
DO_120 and DO_133 to
DO_152 in the above figure are
all transistor output.
DO_101/DO_133
DO_102/DO_134
DO_103/DO_135
DO_104/DO_136
DO_105/DO_137
DO_106/DO_138
DO_107/DO_139
DO_108/DO_140
DO_109/DO_141
DO_110/DO_142
DO_111/DO_143
DO_112/DO_144
DO_113/DO_145
DO_114/DO_146
DO_115/DO_147
DO_116/DO_148
DO_117/DO_149
DO_118/DO_150
DO_119/DO_151
DO_120/DO_152
(Station 0/Station 1): Signal
name of DOUT command
(101/133)
(102/134)
(103/135)
(104/136)
(105/137)
(106/138)
(107/139)
(108/140)
(117/149)
(118/150)
(119/151)
(120/152)
(109/141)
(110/142)
(111/143)
(112/144)
(113/145)
(114/146)
(115/147)
(116/148)
Because the extension output signal specifications are identical to the digital output
signal specifications (Sink type) in Para. 4.9.2, refer to this for further information.