– 114 –
INTERFACE MANUAL
STE 85457
Section 9
Connection of Trigger Input Signal Cable (TRIG) (Option)
The TSL3000E/TSL3100E has eight optional trigger input points. A 0.22-ms
(calculated value) filter is embedded for usual input, but a mere 2.2-
s (calculated
value) filter is embedded for trigger input. To prevent a robot controller malfunction,
input non-chattering, low-noise signals.
The input specifications define the use of bidirectional photocouplers in the input
circuit, so Source type or Sink type is selectable depending on the selection of COM.
To connect the trigger input signal cable, use the connector [XM3D-1521
(socket-type connector), XM2S-1511 (connector cover)] supplied with the robot
controller.
9
2
10
3
11
4
12
5
13
6
14
7
15
8
CASE
User side
Robot controller
COM
COM
1
COM
Source type("+" common)
( ) Signal name of DIN command
TRIG
DI_49
DI_50
DI_51
DI_52
DI_53
DI_54
DI_55
DI_56
(49)
(50)
(51)
(52)
(53)
(54)
(55)
(56)
Connector
Connector
(EXT I/O)
External power
supply detection
circuit
5
4
3
2
1
Note: To use the TRIG signal, supply P24V from the
external equipment.
Unless power is input from the EXT I/O connector on
the front panel, an error occurs in the detection
circuit.
IN_P24V
IN_P24G
P24V
P24G
P24G
P24V
FG
9
2
10
3
11
4
12
5
13
6
14
7
15
8
CASE
User side
Robot controller
COM
COM
1
COM
Sink type("-" common)
TRIG
DI_49
DI_50
DI_51
DI_52
DI_53
DI_54
DI_55
DI_56
(49)
(50)
(51)
(52)
(53)
(54)
(55)
(56)
Connector
Connector
(EXT I/O)
External power
supply detection
circuit
5
4
3
2
1
Note: To use the TRIG signal, supply P24V from the
external equipment.
Unless power is input from the EXT I/O connector on
the front panel, an error occurs in the detection
circuit.
IN_P24V
IN_P24G
P24V
P24G
P24G
P24V
FG
( ) Signal name of DIN command
Fig. 9.1 Connection of trigger input signal cable
The trigger input signal specifications are the same as those for the
TR48DIOCN/TR48DIOC, so see Para. 8.1.1 for specification details.
If the above trigger input is used as the conveyor synchronization start trigger input
function, it cannot be used as the high-speed input function.
Summary of Contents for TSL3000E