DUST- & DRIP-PROOF TYPE SPECIFICATIONS MANUAL
By using the DC24 V power of the controller, a relay, solenoid valve, etc., can be driven.
When the external power is used, GND of the external power should be common to
GND (PG) of the robot controller.
Output
specification:
Rated voltage
:
DC24 V (max. DC30 V)
Rated current
:
1 A
Leak current
:
100 µA or less
• If the DC24 V power is supplied from the robot controller, the total current should be
2 A or less.
• When the external power is used, the total current should also be 2 A or less.
• When a relay, solenoid valve, etc., are connected, it is necessary to use a surge
killer or diode to absorb the surge voltage.
Wiring panel
Details of wiring panel
CN0 hand connector
3xM5 air joint for hand
3xø6 quick-operated
joint for hand
CN4 hand connector
in square connector
(CN20)
JOEP
JOES
JOFP
JOFS
JOEP
JOFP
JOES
JOFS
JOEP
JOES
JOFP
JOFS
3xø6 air tube
Quick-operated joint
STE 80765