Installation
Step 4: Install Stratagy
2-8
Stratagy I&M 06/02
Set up Flash System Hardware
1. If you are wall-mounting the Flash, see the Stratagy Flash Wall-Mounting Template and
Instructions included in the package for instructions on wall mounting the unit
...if the Flash is not going to be wall mounted, place the unit in the site determined.
2. Connect the RJ11C line cords from the Strata single line (analog) station ports to the
corresponding Flash port.
3. If using a UPS, plug it into a dedicated outlet.
Note
A UPS is required in areas where the power source is not stable (frequent power failures,
brownouts, etc.).
4. Connect the six-ft. power supply cable included in the package. Once you have connected the
power supply cable, the Flash performs a self test while booting-up.
The Flash voice ports are off-hook for a short period during startup while Stratagy software loads.
During that time, the status light is Off and should turn On when finished.
IVP8
CAUTION!
See cautions under
before proceeding.
1. Locate the proper slot for the IVP8.
Note
IVP8 can be installed in any
Strata CTX slot. For
Strata DK slot assignments,
see
and
2. Insert the card into the appropriate
slot, and apply firm, even pressure
to ensure proper mating of
connectors (CTX100 shown at
right).
CAUTION!
Do not hit the board for proper seating. This can damage the IVP8 components.
6037
Summary of Contents for Stratagy Flash
Page 20: ...Contents Index viii Stratagy I M 06 02 ...
Page 24: ...Introduction Related Documents Media xii Stratagy I M 06 02 ...
Page 102: ...Configure Stratagy SMDI Serial Integration 4 38 Stratagy I M 06 02 ...
Page 204: ...Customization Examples Auto Menu Examples 8 28 Stratagy I M 06 02 ...
Page 214: ...AMIS Networking AmisNodeList 9 10 Stratagy I M 06 02 ...
Page 222: ...System Reports Report Menu Field Descriptions 10 8 Stratagy I M 06 02 ...
Page 250: ...Special Greeting User ID Mailboxes Operator Mailbox Greeting B 6 Stratagy I M 06 02 ...