Installation
Step 8: Connect Stratagy Admin PC to Stratagy Flash
10
Stratagy Flash Installation Guide 02/02
CAUTION!
Do not install the Stratagy Admin VSA.3x software into an existing Admin2 or
Admin3 directory used for Release 2 systems. If you do, file corruption occurs.
➤
To install Stratagy Admin software
1. Insert the Stratagy Admin disk into the floppy disk drive of the Stratagy Admin PC.
2. Access the DOS prompt (
C:\
).
3. To begin the installation procedure, type
a:install c:\vsa3x
where: x = the version letter of the Admin software you are installing.
Note
It is recommended that you not overwrite the current Stratagy Admin directory but create a
new directory.
4. Press any key to continue. The Stratagy Admin program is installed on drive
C:
in subdirectory
VSA3x
.
Step 8: Connect Stratagy Admin PC to
Stratagy Flash
Communication between the Stratagy Admin PC and the Stratagy Flash is accomplished by one of
two methods: local or remote.
Stratagy Flash uses the serial Port 2 by default to communicate with the Stratagy Admin PC. This
setting can be changed using the admin_port parameter in the Stratagy System Configuration file
(see
Table 2
on
Page 18
for detailed information).
Local Connection
➤
Using a null-modem cable, connect the Stratagy Admin PC to the Stratagy Flash (see
Figure 2
).
A prefabricated cable (SG-ADMCBL), designed expressly for Stratagy Admin communication
with the Stratagy Flash and Stratagy DK, is available from Toshiba.
Figure 2
Stratagy Flash/Stratagy Admin PC Local Connection
Stratagy Admin Cable
Serial COM Port
24 VAC
0.4A 50-60Hz
3089
1
2
Stratagy Admin PC
V O I C
E P R
O C E S
S I N G