– 36 –
Item
16. Setting tem-
perature
correction
switch
Operation flow and applicable data, etc.
1. To improve Cooling/Heating effect
Description
When only poor cooling/heating effect is obtained due to installation place of the indoor unit or
construction of the room, the detection temperature of cooling/heating can be changed.
• Remove the cover of the electric parts box by taking off the mounting screws (3 positions)
and pushing the hooking section.
(The cover of the electric parts box remains hanged to the hinge.)
• There are the selector switches (SW01) on the P.C. board of the electric parts box.
The setting of the detection temperature can be changed by combining No.1 to No.4 switches
of the selector switches (SW01). Adjust the setting of the detection temperature according to
the following table.
No.1
No.2
No.3
No.4
COOL/DRY
HEAT
(°C)
(°C)
OFF
OFF
OFF
OFF
–2
–2
ON
OFF
OFF
OFF
–2
+4
OFF
ON
OFF
OFF
–2
+2
ON
ON
OFF
OFF
–2
0
OFF
OFF
ON
OFF
+4
–2
ON
OFF
ON
OFF
+4
+4
OFF
ON
ON
OFF
+4
+2
ON
ON
ON
OFF
+4
0
OFF
OFF
OFF
ON
+2
–2
ON
OFF
OFF
ON
+2
+4
OFF
ON
OFF
ON
+2
+2
ON
ON
OFF
ON
+2
0
OFF
OFF
ON
ON
0
–2
ON
OFF
ON
ON
0
+4
OFF
ON
ON
ON
0
+2
ON
ON
ON
ON
0
0
←
Factory setting
<Setting at shipment>
ON
ON
SW02
6H
1
ON
6H
2 3 4
B
SW01
TS ADJUST