– 26 –
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (Turbo fan) is operated by DC motor.
The fan rotates in 5 stages in MANUAL mode, and in 5 stages
in AUTO mode, respectively. (Table 1)
Description
* Symbols
UH
: Ultra High
H
: High
M+
:
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate (Cool/Dry/Fan only)
(Table 2) Indoor fan air flow rate (Heat)
Fan speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
COOL
FAN
ONLY
UH
H
M+
M
L+
L
L–
UL
SL
DRY
L–
UL
SL
RAS-M10SMUV-E
RAS-M10SMUCV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
650
590
650
590
650
590
630
570
600
540
570
500
550
480
530
460
500
430
480
410
450
380
370
290
350
270
350
270
350
270
RAS-M13SMUV-E
RAS-M13SMUCV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
680
620
680
620
680
620
630
570
600
540
590
530
550
480
530
460
500
430
480
410
450
380
370
290
350
270
350
270
350
270
RAS-M16SMUV-E
RAS-M16SMUCV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
720
660
720
660
720
660
680
620
650
590
630
570
600
540
550
480
520
450
500
430
450
380
370
290
350
270
350
270
350
270
Fan speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
HEAT
UH
H
M+
M
L+
L
L–
UL
SL
RAS-M10SMUV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
700
640
650
590
640
580
620
560
600
540
570
500
550
480
520
450
500
430
450
380
440
370
420
350
400
330
370
290
350
270
RAS-M13SMUV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
730
670
680
620
640
580
620
560
600
540
590
530
560
490
530
460
500
430
450
380
440
370
420
350
400
330
370
290
350
270
RAS-M16SMUV-E
Fan speed
Air flow rate
(rpm)
(m
3
/h)
750
690
720
660
690
630
670
610
650
590
630
570
600
540
550
480
520
450
470
400
450
380
420
350
400
330
370
290
350
270
+2.5
Ta
[˚C]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
from M+ and L)