– 34 –
Item
13. Select switch on
remote controller
Operation flow and applicable data, etc.
1. Setting remote controller
• Remove the cover, and insert the batteries.
• Push the “CHECK” point and “MODE” button at
once for changing remote controller setting from “A”
to “B”. (Priority is given to “A” setting.)
Description
1. Purpose
This operation is to operate only
one indoor unit using one remote
controller.
2. Description
When operating one indoor unit in
a situation where two indoor units
have been installed in the same
room or nearby rooms, this
operation prevents the remote
controller signal from being
received simultaneously by both
units, thus preventing both units
from operating.
3. Operation
The indoor unit on which the
remote controller selection has
been set to B receives the signal of
the remote controller also set to B.
(At the factory the remote controller
selection is set to A on all the
indoor units. There is no A setting
display.)
START/STOP
PRESET
AM
:
MODE
AUTO
FAN
ECO
TIMER
Hi POWER
SWING
MEMO
FIX
FILTER
RESET CLOCK CHECK
ON
OFF
SET
CLR
When it is “B”, “B” is displayed.
When it is “A” , none is displayed.
Push the “CHECK” point and
“MODE” button at once.
B
2. Setting the unit
• Remove the cover of the electric parts box by taking off the mounting screws (3 positions)
and pushing the hooking section.
(The cover of the electric parts box remains hanged to the hinge.)
• There are the selector switches (SW02) on the P.C. board of the electric parts box.
No.4 of the selector switches (SW02) is provided to select the switch of the remote controller.
Select ON of No.4 of the selector switches (SW02). (OFF: A setting, ON: B setting)
1
ON
ON
SW02
6H
2 3 4
1
ON
6H
2 3 4
F
AN 1
F
AN 2
RE- ST
AR
T
RC A/B
A
B
SW01
TS ADJUST
“B” setting
“A” setting
• Check whether the changed remote controller can operate the indoor unit or not.