Concave part of PMV
Projection of PMV coil
PMV sideways
Turn clockwise
Turn clockwise
(counterclockwise)
(counterclockwise)
Turn clockwise
(counterclockwise)
Taking-off direction
Detail A
Label
Label
4-way valve unit
4-way valve unit
4-way valve coil
4-way valve coil
Label
4-way valve unit
4-way valve coil
Detail B
Coil: Blue
Coil: Green
Coil: Red
Coil: Yellow
No.
11
12
Part name
4-way valve
coil
PMV
Coil: Blue
Coil: Green
Coil: Red
Coil: Yellow
Procedure
∗
Attachment
Mount 4-way valve coil so that the label side
directs upper side of the cabinet.
1. Detachment
1) Perform work of Detachment 1 of
1
.
2) Turn the coil clockwise (counterclockwise) and
then remove it from PMV main unit. (All
4
pcs.)
2. Attachment
1) Mount the PMV coil so that the coil lead wire
taking-out part directs downward.
CAUTION
Coil: Mount yellow coil only so that lead wire
taking-out part directs upward.
2) Match the positioning projection of coil with
the concave part of PMV unit surely and fix it.
Remarks
FILE NO. SVM-18052
- 103 -