Modem test (Not Used)
For this subtest, connect the modem PCB and RJ11 connector with a harness. Use the
dedicated “FAT-MODE inspection device (product code: QE2000P01 made by Nitto Denki
Seisakusyo)” for the tests.
##################################################################
###### AC97' Modem Controller Diagnostics program #######
##################################################################
*
*
*
1 ............ (ICHx)
*
*
*
*
2
............
(ICH6)
*
*
*
******************************************************************
.... Press test number[1-2] ?
To execute Modem test, press
2
and
Enter
. Following message will appear:
[Modem loopback test !]
ICHx MDC Test Program with Modem Sound (Line Test)
Version X.X
* Scorpio Modem Initialize
:OK
* Digital Loopback Test
:OK
* RJ11 Connector Check (LED)
:(Operator’s Check!!)
OK
is displayed when a error is detected,
NG
is display when a error is not detected.
NOTE: The menu displayed by your computer may be slightly different from the one
shown above.
RJ11 Connection Check (LED) (Operator’s Check LED) test will be executed, and the
following message will appear:
...Press Key (Y = OK , N =NG)
If the color in the LED of the connection checker is orange, press
Y
,
otherwise, press
N
.
Summary of Contents for Qosmio F60 Series
Page 11: ...1 Hardware Overview 1 2 Qosmio F60 Series Maintenance Manual 960 796 CONFIDENTIAL ...
Page 43: ...Troubleshooting Procedures 2 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 119: ...Tests and Diagnostics 3 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 3 ...
Page 293: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 398: ... CONFIDENTIAL Appendices ...
Page 399: ...Appendices App ii CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 459: ...Appendix E Key Layout TECRA 9100 Maintenance Manual 960 347 3 ...