Troubleshooting Procedures
Procedure 2
Connector Check and Replacement Check
The connection of cables, boards and module may be defective. Otherwise, they may be faulty.
Disassemble the computer following the steps described in Chapter 4 and perform the
following checks:
Check 1
Make sure the HDMI TV is firmly connected to CN5350 on the system board.
If any of the connections are loose, reconnect firmly and repeat Procedure 1. If
there is still an error, go to Check 2.
Check 2
It checks whether there are any abnormalities in a setup of HDMI TV, and returns
to Procedure 1. In addition, a HDMI setup of television should check "the
instructions manual of attachment on HDMI TV." If the problem still exists,
perform Check 3.
Check 3
The HDMI TV cable may be damaged. Replace it with a new one following the
instructions in Chapter 4,
Replacement Procedures
. If the problem still exists,
perform Check 4.
Check 4
The HDMI TV may be damaged. Replace it with a new one following the
instructions in Chapter 4,
Replacement Procedures
and check the operation. If the
problem still exists, perform Check 5.
Check 5
The system board may be damaged. Replace it with a new one following the
instructions in Chapter 4,
Replacement Procedures
.
2-76
[CONFIDENTIAL] Qosmio F60 Series Maintenance Manual (960-796)
Summary of Contents for Qosmio F60 Series
Page 11: ...1 Hardware Overview 1 2 Qosmio F60 Series Maintenance Manual 960 796 CONFIDENTIAL ...
Page 43: ...Troubleshooting Procedures 2 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 119: ...Tests and Diagnostics 3 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 3 ...
Page 293: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 398: ... CONFIDENTIAL Appendices ...
Page 399: ...Appendices App ii CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 459: ...Appendix E Key Layout TECRA 9100 Maintenance Manual 960 347 3 ...