Troubleshooting Procedures
2-18
[CONFIDENTIAL] Qosmio F60 Series Maintenance Manual (960-796)
E3V output
Error code Meaning
60h
E3V voltage is over 3.96V.
61h
E3V voltage is under 2.81V when the computer is powered on.
62h
E3V voltage is under 2.81V when the computer is booting up.
63h
E3V voltage is output when the computer is powered off.
64h
E3V voltage is under 2.81V when EV power is maintained.
1R5-B1V
output
Error code Meaning
70h
1R5-B1V voltage is over 1.80V.
71h
1R5-B1V voltage is under 1.28V when the computer is powered on.
72h
1R5-B1V voltage is under 1.28V when the computer is booting up.
73h
1R5-B1V voltage is output when the computer is powered off.
74h
1R5-B1V voltage is under 1.28V when BV power is maintained.
1R05-P1V output
Error code Meaning
80h
1R05-P1V voltage is over 1.26V.
81h
1R05-P1V voltage is under 0.89V when the computer is powered on.
82h
1R05-P1V voltage is under 0.89V when the computer is booting up.
83h
1R05-B1V voltage is output when the computer is powered off.
PPV output
Error code Meaning
90h
PPV voltage is over 1.68V.
91h
PPV voltage is under 0.00V when the computer is powered on.
92h
PPV voltage is under 0.55V when the computer is booting up.
Summary of Contents for Qosmio F60 Series
Page 11: ...1 Hardware Overview 1 2 Qosmio F60 Series Maintenance Manual 960 796 CONFIDENTIAL ...
Page 43: ...Troubleshooting Procedures 2 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 119: ...Tests and Diagnostics 3 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 3 ...
Page 293: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 398: ... CONFIDENTIAL Appendices ...
Page 399: ...Appendices App ii CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...